Mr. Bernard P. Orlan May 29, 2002 Indoor Air Quality Assessment Page 3 H.S. for Leadership & Public Sendee (MS94 i ATC Project No. 15-19125-0290

Real-Time environmental Measurements

ATC collected one hundred and forty (140) sets of real-time environmental measurements consisting of one hundred and twenty-eight (128) in the school building and twelve (12) outdoors. All fourteen floors of the school were surveyed. Field data sheets are found in the .Attachment. Readings were collected in the morning and evening. The results are described below.

Temperature

Indoor dry bulb temperature measurements ranged from 74.4°F to 81.9°F. Five (5) of the indoor measurements for temperature were above and no measurements were below the range of 73 to 79°F (at 50 percent relative humidity) recommended by ASHRAE Standard 55-1992 during the summer season. The outdoor temperature ranged from 77.5 to 80.4°F.

Relative Humidity

The relative humidity indoors ranged from 51.0 percent to 58.6 percent. All of the indoor measurements for relative humidity were within the ASHRAE-recommended range of 30 to 60 percent for occupant comfort. The outdoor relative humidity range was 55.1 to 59.8 percent.

Carbon Dioxide Concentration

Carbon dioxide concentrations indoors ranged from 501 ppm to 1121 ppm. All of the indoor measurements for CO2 were below the ASHRAE Standard 62-1999 recommended maximum concentration of <700 ppm above the background level. The outdoor (background) CO2 concentration was 689 ppm. Therefore, the maximum acceptable level of CO2 at this location was 1389 ppm (background level 700 ppm). Levels above the recommended maximum do not indicate a health risk. Carbon dioxide measurements are used as an indicator of available outdoor air. The primary source of CO2 indoors is occupant respiration.

Carbon Monoxide Concentration

Carbon monoxide concentrations indoors ranged from 1 ppm to 2 ppm. These concentrations were below the NPAAQS/ASHRAE guideline of 9 ppm. 'The outdoor CO concentrations ranged from 1 ppm to 3 ppm.

Respirable Particulates (PM2,5)

Respirable particulate concentrations* indoors ranged between 2 pg/m^ to 24 pg/m^ with an average 11 pg/m^' None of the indoor measurements for PM2.5 were above the NPAAQS of 65 pg/m^ 24-hour average concentration of particulate matter 2.5 micrometers or less in aerodynamic diameter and the USEPA recommended concentration of 40 pg/m3 for sensitive individuals such as asthmatic people and children. The outdoor respirable particulate concentrations ranged from 53 pg/m^ to 82 pg/m^ with an average of 67 pg/m^.

CITY_21MC100_003079575

NYC-WTC_000291962

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000291962Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000211859

Letter and report from ATC Associates detailing indoor air quality measurements collected at the school on March 25, 2002, to evaluate possible contamination.

Similar indexed content

NYC-WTC_000399366

May 15, 2002 IAQ measurements report for BOE.

Similar indexed content

Compare copies and versions →