3 ■

. Certified Testing Laboratories, Inc. DATE:. May 9, 2002 Civetta-Cousins JV LAB NO: 12737

Compressive Strenghts

1 2 3 A 7 Days (psi) •. 4100. 4490 4990 5380 3980 4550 4930 5430

average 4040 4520 4960 . 5410

28 Days (psi) 5270 5730 . 6420 6720 5150 5540 63S0 6670 ■ 5180 5660 6260 6750 .5270 . 5780 6330 6830

average 5220 5700 6350 6740

Laboratory sized batches vrere made. Six cylinders vere cast.for each "batch and the preceding test results vere obtained from these cylinders . The test cylinders had been scored in a moisture room at the temperature of 72 degrees .? and 95X humidity from the date of casting until the date .of testing. The cement and vater are for a slump of four inches, with aggregates noted ( + one inch in field). Based on our laboratory results, we suggest using MIX #4 for 5000 psi concrete.

NOTE: Add WR Grace Daraset when necessary at rate depending on ambient temperature Respectfully submitted. below 50°F, from certiked testing LABORATO! 10 oz/lOO CW to 40 oz/100 CW. As follows: A 40to50°-10o2/100cw 30to40’-2_Qoz/X00cw ■iichard/J. iZaloum, PE ZOtoSO^-dboz/lOOcw NYC CERUFICATE OF QUALIFICATION #3 10to20°-40oz/100cw

M256

CITY_21MC100^004713852

NYC-WTC_000290083

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000290083Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →