NYC-WTC_000340053
OSHA asbestos and noise sampling results through 12/18; rubble pile focus.
25 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗OSHA asbestos/noise sampling update at WTC debris area; results show most levels below limits.
NYC-WTC_000289985–000289986OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
OSHA SAMPLING RESULTS SUMMARY AS OF 12/20
Asbestos: A total of 872 air monitoring samples for asbestos have been taken. From 9/13 -9/21, 177 samples were taken in the financial district. They were taken on OSHA personnel as they walked within certain predetermined zones. Results revealed asbestos concentrations ranging from ND (none detected) to .037 f/cc., well below OSHA’s peimissible exposure limit (PEL) of .1 f/cc. After 9/21, sampling focused on the mbble pile and those workers working on or immediately next to it. 82 of the samples analyzed exceeded OSHA’s limit via PCM analysis. However, upon further analysis using discriminating counting methods and/or TEM analysis, the number of asbestos fibers found dropped dramatically to below detectable levels or well below .1 f/cc.
Carbon Monoxide: A total of 77 personal samples of workers on the rubble pile showed results ranging from 1 ppm to 34 ppm which are well below the OSHA 50 ppm permissible exposure limit.
Noise: OSHA has been conducting noise monitoring in the rubble pile. 41 personal samples have been conducted on employees performing (or working near) various operations such as jack hammering, drilling and equipment operations. Employee’s exposure to the noise range from 73.7 dBA to 94.5 dBA. OSHA’s permissible noise exposure for construction is 90 dBA. One personal sample and one area sample during core drilling operations exceeded the OSHA noise PEL of 90 dBA. OSHA continues to recommend the use of appropriate hearing protection for workers performing tasks where high noise levels are likely to be encountered. Respirable Silica: The overwhelming majority of the 402 silica samples show no detectable levels of airborne silica. However, fourteen exposures exceeded the PEL. The highest sample result was approximately nine times the OSHA limit (pre-drillers working on the slurry or “bathtub” wall). The other twelve elevated exposures were approximately one to seven times the OSHA limit. These exposures occurred during: 1) rabble removal and loading operations near the Winter Garden; 2) during the breaking up of concrete in the pit; 3) while core drilling the concrete slurry wall, and 4) while chipping concrete with power tools during demolition activities at 7 WTC’s parking garage. Most of the work areas where apparent overexposures to silica occurred were in the rabble pile; an area where OSHA continues to encourage the use of respiratory protection. Volatile Organic Compounds: OSHA has taken 608 samples for (VOCs) such as acetaldehyde, acrolein, acrylonitrile, benzene, 2-butanone, carboftirans, chlorodiphenyl (PCB), ethyl benzene, formaldehyde. Freon R-22 (chlorodiflouromethane), hexone, isocyanates (e.g. MDI, TDI), perchloroethylene, phosgene, styrene, toluene, 1-3 butadiene, trichloroethylene, vinyl chloride, glutaraldehyde, and xylene. Screening samples initially showed elevated levels of some organic chemicals resulting from the fires burning in the mbble pile. Subsequent personal and area samples show worker exposure levels to be below OSHA limits. However, one personal sample result for benzene was found to be at the 8-hr. OSHA Allowable Limit concentration of 1 ppm. This was found on a backhoe operator moving debris. See information below for polynuclear aromatics. Freon R-22, phosgene and dioxin. Oxides of Nitrogen/ Sulfur: Sampling on grappler operators on the rubble pile, and on employees manning fruck wash stations revealed trace levels of nitric oxide and nitrogen dioxide. SO, personal and area results were found to be below OSHA limits.
Page 1 of 2
CITY_21MC100_002959218
NYC-WTC_000289985
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
No available related records indexed in this group.
NYC-WTC_000340053
OSHA asbestos and noise sampling results through 12/18; rubble pile focus.
25 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000304594
Asbestos air monitoring results from 9/13 onward; rubble pile focus and noise monitoring.
25 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000362288
Asbestos sample totals and rubble-pile results, with noise monitoring note.
25 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000339852
Detailed WTC asbestos sampling data with specific locations and fiber/cc measurements.
25 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000280312
OSHA asbestos and rubble-pile results; workers’ exposure levels below limits overall.
25 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000362284
Asbestos air samples with rubble-pile exposure and non-detected levels.
25 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000349343
Summary of asbestos air monitoring results; ND to 0.037 f/cc; PEL well above measurement.
25 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000354283
Summary through Dec 20: ND to .037 f/cc asbestos; 82+ rubble pile samples exceeding limit initially, later reduced.
25 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000263572
Emergency Management report: asbestos and noise monitoring results during rubble pile demolition.
25 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000339850
Asbestos and worker-sample data from the rubble pile with exposure levels and limits.
25 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000360730
Rubble-pile exposure and asbestos monitoring; TEM analysis confirms lower fiber levels.
25 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000339841
OSHA sampling results for asbestos, including counts, locations, and exposure levels near the WTC rubble pile.
25 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000362288
Asbestos sample totals and rubble-pile results, with noise monitoring note.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000339850
Asbestos and worker-sample data from the rubble pile with exposure levels and limits.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000339841
OSHA sampling results for asbestos, including counts, locations, and exposure levels near the WTC rubble pile.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000360730
Rubble-pile exposure and asbestos monitoring; TEM analysis confirms lower fiber levels.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000355962
OSHA summary of asbestos air monitoring, rubble pile and financial district results.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000349343
Summary of asbestos air monitoring results; ND to 0.037 f/cc; PEL well above measurement.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000340053
OSHA asbestos and noise sampling results through 12/18; rubble pile focus.
Similar indexed content
NYC-WTC_000304594
Asbestos air monitoring results from 9/13 onward; rubble pile focus and noise monitoring.
Similar indexed content
NYC-WTC_000362288
Asbestos sample totals and rubble-pile results, with noise monitoring note.
Similar indexed content
NYC-WTC_000339852
Detailed WTC asbestos sampling data with specific locations and fiber/cc measurements.
Similar indexed content
NYC-WTC_000280312
OSHA asbestos and rubble-pile results; workers’ exposure levels below limits overall.
Similar indexed content