Lab report on asbestos air/dust, Lower Manhattan, Mar 2002

Machine-extracted title · confidence 25%

Review and summary of asbestos-related air and dust testing after WTC collapse; clarifies OSHA/settled dust guidance.

NYC-WTC_000289653–000289658
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

the debris field and those workers working in or immediately next to it. 144 of the samples analyzed exceeded OSHA’s limit via PCM analysis. However, upon further analysis using discriminating counting methods and/or TEM analysis, the number of asbestos fibers found dropped dramatically to below detectable levels or well below 0.1 f/cc. FOR THIS SECTION, CAN WE SEPARATE OUT SOME EARLY RESULTS FROM THE LATE ONES?

ATSDR Indoor Air Quality Study

At the request of NYC DOH, the Federal Agency for Toxic Substances and Disease Research (ATSDR) conducted tests in 59 apartments in 30 geographically representative buildings in lower Manhattan in November and December 2001. Testing was also conducted in four buildings above 59th Street to provide information on the background level of various substances present indoors in New York City. Using widely accepted testing methods, the agency looked for several materials - including asbestos - that are common building components or could potentially cause short and long-term health problems.

A total of 117 samples were taken from 30 buildings in lower Manhattan and analyzed for airborne asbestos fibers. Samples were taken inside residences, in common areas within residential buildings, and outside of the buildings. The air samples from inside the buildings showed no elevated levels of asbestos. Levels were similar to those seen in areas not affected by the World Trade Center collapse.

The analysis of 98 dust samples for asbestos taken from the inside and outside of residential buildings in lower Manhattan indicated that while 20% were above background levels, only two samples which were taken from outdoors required abatement. Professional abatement work was completed in this area.

Sampling of Indoor Air and Dust Tests Reported by Building Owners

The NYC Department of Environmental Protection (NYC DEP) has received reports of bulk and air sample analyses submitted by building owners. These samples are collected by individuals who are trained and certified in the proper asbestos sampling techniques, and are analyzed by NYS DOH approved asbestos analytical laboratories.

NYC DEP has received results of 1,999 indoor bulk sample analyzed as of March 4, 2002. Of those 128 were found to contain asbestos concentrations greater than the City’s regulatory threshold of 1% asbestos by weight. In all such cases the NYC DEP required abatement in accordance with City regulations.

CITY_21MC100_008911981

NYC-WTC_000289657

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000289657Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000455321

DOH letter explaining asbestos test results in lower Manhattan residences.

Similar indexed content

Compare copies and versions →