the debris field and those workers working in or immediately next to it. 144 of the
samples analyzed exceeded OSHA’s limit via PCM analysis. However, upon
further analysis using discriminating counting methods and/or TEM analysis, the
number of asbestos fibers found dropped dramatically to below detectable levels
or well below 0.1 f/cc. FOR THIS SECTION, CAN WE SEPARATE OUT SOME
EARLY RESULTS FROM THE LATE ONES?
ATSDR Indoor Air Quality Study
At the request of NYC DOH, the Federal Agency for Toxic Substances and
Disease Research (ATSDR) conducted tests in 59 apartments in 30
geographically representative buildings in lower Manhattan in November and
December 2001. Testing was also conducted in four buildings above 59th Street
to provide information on the background level of various substances present
indoors in New York City. Using widely accepted testing methods, the agency
looked for several materials - including asbestos - that are common building
components or could potentially cause short and long-term health problems.
A total of 117 samples were taken from 30 buildings in lower Manhattan and
analyzed for airborne asbestos fibers. Samples were taken inside residences, in
common areas within residential buildings, and outside of the buildings. The air
samples from inside the buildings showed no elevated levels of asbestos. Levels
were similar to those seen in areas not affected by the World Trade Center
collapse.
The analysis of 98 dust samples for asbestos taken from the inside and outside
of residential buildings in lower Manhattan indicated that while 20% were above
background levels, only two samples which were taken from outdoors required
abatement. Professional abatement work was completed in this area.
Sampling of Indoor Air and Dust Tests Reported by Building Owners
The NYC Department of Environmental Protection (NYC DEP) has received
reports of bulk and air sample analyses submitted by building owners. These
samples are collected by individuals who are trained and certified in the proper
asbestos sampling techniques, and are analyzed by NYS DOH approved
asbestos analytical laboratories.
NYC DEP has received results of 1,999 indoor bulk sample analyzed as of March
4, 2002. Of those 128 were found to contain asbestos concentrations greater
than the City’s regulatory threshold of 1% asbestos by weight. In all such cases
the NYC DEP required abatement in accordance with City regulations.
CITY_21MC100_008911981
NYC-WTC_000289657
OCR can misread numbers and units. Confirm readings against the page image before using them.