NYC-WTC_000338238
Results of settled dust sampling in 30 residential buildings near the WTC site.
5 shared non-person entities · 1 shared topics · similarity 0.972
machine-extracted · confidence unavailable · Check page ↗Narrative on health concerns and rationale for sampling dust and air post-9/11.
NYC-WTC_000289613–000289615OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Manhattan show the widespread presence of fibrous glass [see table?]. In 17 of the 29 buildings where indoor samples were collected, fibrous glass was found at or above 5% in at least one location. Fibrous glass was found at or above 15% in 9 of the 14 outdoor locations where enough available settled dust was available to sample. Although no outdoor surface dust was collected from the comparison homes above 59* Street (not enough dust available to collect), it was not detected in any of the indoor locations tested.
How do these results compare to typical levels in the environment? DT white paper?
What is known about human exposure to Jibrous glass and health ejfects? There are two ways that people can be exposed to fibrous glass-^Ohtact with skin and eyes, and breathing in fibers that are in the air. The irritative effects from fibrous glass are from the large diameter fibers that will embed in the skin, eyes, nose and throat. Less is known about the effects of the smaller diameter fibers that can be inhaled into the lungs as they have been in use a much shorter period of time.
Dermal: All types of glass fibers can cause irritation of the eyes and skin on contact. The fibers become imbedded in the skin and create a mechanical irritation. This results in the typical irritant effects of redness, swelling, itching, tearing, and burning. These effects are generally seen only in the areas of the skin that came in contact with the glass fibers. The results are typically temporary and when the fibers are removed, the symptoms begin to fade.
Inhalation: Larger fibers that are inhaled can cause an irritation of the nose, throat, trachea and bronchi by imbedding in the tissue. Symptoms of this irritation include itchy nose with a clear mucous secretion, a dry scratchy throat that needs clearing frequently, paroxysms of coughing, difficulty breathing, and wheezing. Studies that have looked at the effects of exposure to the shorter diameter fibers of the common types of fibrous glass that can be inhaled deep into the lungs have not shown a consistent association with lung disease or cancer. A special-purpose glass fiber called refractory ceramic fibers has been linked to lung cancer in recent studies.
/Irt' there regulatory standards forJibrous glass? There are no environmental or occupational (worker) regulatory standards specifically for fibrous glass in settled dust or in air. There are two occupational guidelines for fibrous glass in air; there are no occupational guidelines for fibrous glass in settled dust. The National Institute for Occupational Safety and Health (NIOSH) guideline is 3 fibers per cubic centimeter of air (3 f/cc). The American Conference of Governmental Industrial Hygienists guideline is 1 f/cc (respirable fibers). These guidelines are based upon the irritative effects of exposure.
fVhat do the levels found in Lower Manhattan mean to the community's health ? The levels found in the settled dust samples cannot be used to predict whether people will experience skin or eye irritation, and they cannot predict the levels of fibers that might become airborne. The levels found do indicate that proper and frequent indoor cleaning (wet mopping,
CITY_21MC100_006661332
NYC-WTC_000289614
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000338238
Results of settled dust sampling in 30 residential buildings near the WTC site.
5 shared non-person entities · 1 shared topics · similarity 0.972
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000320641
Public communication guidance on residential dust/asbestos in lower Manhattan during cleanup.
5 shared non-person entities · 1 shared topics · similarity 0.949
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000353784
DOHMH/ATSDR air and dust sampling results around 400 Chambers Street residences.
3 shared non-person entities · 1 shared topics · similarity 0.945
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000353764
Continuation of WTC-related air and settled-dust sampling results for 31 N. [name].
3 shared non-person entities · 1 shared topics · similarity 0.943
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000353789
DOHMH/ATSDR report on air/dust sampling around 400 Chambers Street buildings.
3 shared non-person entities · 1 shared topics · similarity 0.943
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000319828
DOH release on findings from indoor air sampling and importance of cleaning.
3 shared non-person entities · 1 shared topics · similarity 0.943
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000208376
Report on environmental sampling of air and settled dust at a residential building in lower Manhattan following the World Trade Center collapse.
3 shared non-person entities · 1 shared topics · similarity 0.943
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000242212
DOHMH/ATSDR report on residential dust sampling after WTC collapse.
3 shared non-person entities · 1 shared topics · similarity 0.943
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000353779
Report of air and settled dust sampling around 400 Chambers Street post-WTC collapse.
3 shared non-person entities · 1 shared topics · similarity 0.942
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000319147
Air and settled dust results for 80 Warren Street in the World Trade Center response program.
3 shared non-person entities · 1 shared topics · similarity 0.942
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000319521
Results report for air and settled dust samples around 30 WTC-impacted buildings.
3 shared non-person entities · 1 shared topics · similarity 0.942
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000141740
Press release from the NYC Department of Health presenting findings from indoor air sampling in Lower Manhattan.
3 shared non-person entities · 1 shared topics · similarity 0.948
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000338238
Results of settled dust sampling in 30 residential buildings near the WTC site.
Similarity score 0.968 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000320641
Public communication guidance on residential dust/asbestos in lower Manhattan during cleanup.
Similarity score 0.956 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000320259
Draft report on potential exposures to airborne and settled surface dust in residential areas.
Similarity score 0.954 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000320617
ATSDR indoor air/dust sampling advisory for WTC area residences; guidance and monitoring discussion.
Similarity score 0.954 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000289637
Table of fiber types with TLV values for MMVFs, glass fibers, and related materials.
Similarity score 0.954 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000243169
Department memo referencing 9/11 toxic hazards at Ground Zero site.
Similarity score 0.953 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000338238
Results of settled dust sampling in 30 residential buildings near the WTC site.
Similar indexed content
NYC-WTC_000320641
Public communication guidance on residential dust/asbestos in lower Manhattan during cleanup.
Similar indexed content
NYC-WTC_000141740
Press release from the NYC Department of Health presenting findings from indoor air sampling in Lower Manhattan.
Similar indexed content
NYC-WTC_000353784
DOHMH/ATSDR air and dust sampling results around 400 Chambers Street residences.
Similar indexed content
NYC-WTC_000353764
Continuation of WTC-related air and settled-dust sampling results for 31 N. [name].
Similar indexed content