Asbestos in air testing data, ID-160

Machine-extracted title · confidence 32%

Air sample results for asbestos with limits and average values reported.

NYC-WTC_000289580
Page image
Scanned page image, NYC-WTC_000289580
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ASBESTOS jN AIR - iTiwi gaiuc Method 'tloO) tile./.vA/osha asbestos in air.litnii

..........................................................................

i........................................................................................................... technical Links > Sampling & Analytical Methods > Index

ASBESTOS IN AIR

Method No.: ID-160

Matrix: Air

OSHA Permissible Exposure Limits 0.1 fiber/cc Time Weighted Average: 1.0 fiber/cc Excursion Level (30 minutes):

Collection Procedure: A known volume of air is drawn through a 25-mm diameter cassette containing a mixed-cellulose ester filter. The cassette must be equipped with an electrically conductive 50-mm extension cowl. The sampling time and rate are chosen to give a fiber density of between 100 to 1,300 fibers/mm^^^ on the filter.

Recommended Sampling Rate: 0.5 to 5.0 liters/minute (L/min)

Recommended Air Volumes Minimum: 25 L Maximum: 2,400 L

Analytical Procedure: A portion of the sample filter is cleared and prepared for asbestos fiber counting by Phase Contrast Microscopy (PCM) at 400X.

Detection Limit: 5.5 fibers/mm^^^ or 0.001 fibers/cc (2,400 L Air Volume)

Precision CV; 0.12 (at 100 fibers/mm^2))

Method Classification: Validated Method

Date (Date Revised): July 1988 (July 1997)

Physical Scientist: Daniel T. Crane

Commercial manufacturers and products mentioned in this method are for descriptive use only and do not constitute endorsements by USDOL-0SHA. Similar products from other sources can be substituted.

1 of21 9/19/01 10:59 AM

CITY_21MC100_002946229

NYC-WTC_000289580

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000289580Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000321065

Revision copy of NYC ER asbestos air sampling results with TEM and AHERA data.

Similar indexed content

NYC-WTC_000451966

Air sampling results by PCM and TEM for 9/29/01.

Similar indexed content

NYC-WTC_000443589

Asbestos sampling results over 9/29-9/30/01; TEM/PCM data and AHERA metrics.

Similar indexed content

Compare copies and versions →