NYC-WTC_000374708
ATC IAQ measurements at P.S. 150M for BOE air quality assessment, April 26, 2002.
13 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗IAQ measurements collected for P.S. 150M; March 22, 2002.
NYC-WTC_000289410–000289413OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Mr. Bernard P. Orlan March 25. 2002 Indoor Air Quality Assessment Page 4 ]'. S. 150M ATCPrpiect No. 15-19125-0289
’ The measurements made during this assessment were instantaneous readings, the XPAAQS is a 24-hour average.
Tl'OC Corieenlrations
'fVOCs were not detected anynvhere inside the building (0.0 ppm). Tlie outdoor TVOC concentration was also 0.0 pom.
OBSERVATIONS
During this assessment, ATQ noted the following; • There was construction work going on in the plaza; • The school building was occupied at the time of the assessment; • No smoke odor was detected in the building;
FINDINGS
Based on the real-time measurements, the following findings are presented;
1. Concentrations of CO, COg and TVOCs were within applicable standards and guidelines; 2. None of the indoor or outdoor PM2.5 measurements were above the NPAAQS of 6,5 pg/m-'’ or abo\'e the USEPA recommended PM2.5 concentration of 40 pg/m^ for sensitive individuals and children. 3. Seventeen (17) of the temperature measurements were above the range 01’68 to 75O p (at 50 percent relative humidity) recommended by ASHRAE .Standard 55-1992 during the heating season (wintertime conditions). 4. All measurements of relative humidity were below the ASHRAE recommended range of 30 to 60 percent for occupant cornfort.
It IS our pleasure to provide these indoor air quality services to the New 'I'ork City Board of Education. If you have any questions about this report, please call (2121 353-8280, extension 211 or 212.
■Sincerely, Reviewed by; .4 TC ASSOCIA TES INC.
I Yiannis Efstathiou James R. Colm, CIH, CSP Senior Project Manager Regional Manager Industrial Hygiene Division Attachment
CITY_21MC100_002954219
NYC-WTC_000289413
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000374708
ATC IAQ measurements at P.S. 150M for BOE air quality assessment, April 26, 2002.
13 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000300743
ATC provides IAQ evaluation for PS 150M in Mar 2002.
13 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000289478
ATC memo detailing IAQ measurements conducted at PS 150M for BOE re-occupancy.
12 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000253571
ATC IAQ measurements at P.S. 150M for pre-occupancy evaluation by BOE.
13 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000289354
Report of indoor air quality measurements conducted February 8, 2002.
12 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000289398
Indoor air quality measurements conducted at P.S. 150M for BOE prior to occupancy.
13 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000289426
IAQ measurements collected at PS 150 M for re-occupancy evaluation.
12 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000289370
ATC indoor air quality measurements at PS 150 M for BOE prior to re-occupancy.
12 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000289310
Indoor air quality measurements conducted for school prior to re-occupancy.
13 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000289358
Indoor air quality measurements collected February 11, 2002 for PS 150M.
13 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000374700
ATC reports IAQ measurements taken April 24, 2002 at P.S. 150M for BOE air quality review.
13 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000375441
Indoor air quality measurements at P.S. 150M, school building prior to re-occupancy.
13 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000289426
IAQ measurements collected at PS 150 M for re-occupancy evaluation.
Similarity score 0.992 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000289370
ATC indoor air quality measurements at PS 150 M for BOE prior to re-occupancy.
Similarity score 0.992 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000300743
ATC provides IAQ evaluation for PS 150M in Mar 2002.
Similarity score 0.991 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000253571
ATC IAQ measurements at P.S. 150M for pre-occupancy evaluation by BOE.
Similarity score 0.991 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000289478
ATC memo detailing IAQ measurements conducted at PS 150M for BOE re-occupancy.
Similarity score 0.991 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000187677
Cover letter from ATC Associates submitting an indoor air quality assessment report for PS150M collected on March 18, 2002.
Similarity score 0.990 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000374708
ATC IAQ measurements at P.S. 150M for BOE air quality assessment, April 26, 2002.
Similar indexed content
NYC-WTC_000300743
ATC provides IAQ evaluation for PS 150M in Mar 2002.
Similar indexed content
NYC-WTC_000289478
ATC memo detailing IAQ measurements conducted at PS 150M for BOE re-occupancy.
Similar indexed content
NYC-WTC_000253571
ATC IAQ measurements at P.S. 150M for pre-occupancy evaluation by BOE.
Similar indexed content
NYC-WTC_000289354
Report of indoor air quality measurements conducted February 8, 2002.
Similar indexed content