Air sampling results, Sept 27, 2001, NIOSH/NYDOH

Machine-extracted title · confidence 41%

Interim air results near debris pile; asbestos and carbon monoxide measurements reported.

NYC-WTC_000287804
Page image
Scanned page image, NYC-WTC_000287804
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Centers for Disease Control and Prevention National Institute for Occupational Safety and Health Air Sampling Report Thursday, September 27, 2001

Investigators from the National Institute for Occupational Safety and Health (NIOSH) collected air samples in areas immediately adjacent to the debris pile and on personnel actively involved in rescue efforts on or in the vicinity of the debris pile to characterize occupational exposures. Below are the sampling results for Thursday, September 27, 2001.

Air Samples

Acid Gases • 2 personal and 4 area air samples were collected for acid gases o Trace amounts of acid gases were detected on all personal and area air samples (1 personal air sample had a time-weighted average sulfuric acid concentration of 0.8 mg/m’)

Asbestos • 76 personal air samples were collected by NYDOH contractors for asbestos o Most personal sample 8-hour time-weighted average concentrations were at or below 0.024 fibers/cc as determined by PCM (2 had concentrations of 0.10 and 0.18 fibers/cc) o Most short-term exposure limit samples were below 0.067 fibers/cc as determined by PCM (3 of these had concentrations of 0.12,0.17, and 1.8 fibers/cc) o 8 personal air samples were also analyzed by TEM; no asbestos was detected on 2 air samples, 5 air samples had concentrations at or below 0.062 asbestos fibers/cc, and 1 air sample had a concentration of 0.28 asbestos fibers/cc)

Carbon Monoxide • 9 real-time personal breathing zone samples were collected for carbon monoxide o Most personal time-weighted average concentrations were at or below 24 ppm (1 torch cutter had a time-weighted average concentration of 41 ppm) o A single peak of 1368 ppm was observed on a concrete saw operator • 11 real-time area samples were collected at locations near specific work tasks on or near the debris pile for carbon monoxide o Most area time-weighted average concentrations were at or below 24 ppm (1 sample near a concrete saw operator had a time-weighted average concentration of 40 ppm)

Diesel Exhaust (Elemental Carbon) • 1 personal and 3 area air samples were collected for diesel exhaust (elemental carbon) o The personal air sample concentration was 0.017 mg/m’ o No elemental carbon was detected on any of the area air samples

Polynuclear Aromatic Hydrocarbons (PAHs) • 1 personal and 3 area air samples were collected for PAHs o Very low concentrations of 5 different PAHs were measured o Trace amounts of 4 other PAHs were also identified

K.M. Wallingford 11/2/01

CITY_21MC100_002967953

NYC-WTC_000287804

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000287804Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →