Daily environmental monitoring summary, Oct 28–29, 2001

Machine-extracted title · confidence 44%

EPA daily monitoring summary for Oct 28–29, 2001 at Center site and surroundings.

NYC-WTC_000287139–000287141
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document WTC Enviromental Monitoring: October 28 & 29, 2001 wysiwyg;//7/http;//www.epa.gov/epahonic/'w!c/epa-oshal0280l.hln

VOCs - Sampling for volatile organic compounds (VOCs) was conducted October 26 through October 28 in the direct area of the debris pile at ground zero. On each of the three days, benzene exceeded the OSHA time-weighted permissible exposure level at two locations. On October 26 five samples were collected and analyzed for Freon-22 (chlorodiflouromethane), Freon-22 was not detected in these samples. Freon-22 was detected and confirmed in samples collected from within the debris pile of the North Tower and in the debris pile of the South Tower, both at ground level, in samples collected on October 27 and within the debris pile of the North Tower on October 28, also at ground level. Levels detected were well below the NIOSH recommended exposure limit of 1,000 parts per million (ppm). EPA is working with the local agencies and health and safety officers working at ground zero to closely monitor this situation so that workers can take appropriate precautions.

PM 2.5 - Monitoring for fine particulate matter (particles less than 2.5 micrometers in diameter) was conducted October 26 through October 27 at Pace University, the Borough of Manhattan Community College, the U.S. Coast Guard building located in Battery Park and Albany Street at Battery Park City. All 24-hour average values were below the National Ambient Air Quality Standard (NAAQS) of 65 ug/m3 for all stations. These results were also less than 40 ug/m3, a level on the EPA Air Quality Index that indicates when air quality is unhealthy for sensitive populations (e.g., those with respiratory illnesses).

Direct Air Readings - Using portable monitors, direct air readings were taken in and around ground zero on Qctober 27 and October 28. Several carbon monoxide readings were detected above the National Ambient Air Quality Standard (NAAQS) 8-hour average of 9 ppm during the early afternoon on October 27 and during the late morning on October 28; however the readings were below the NAAQS 1-hour average of 35 ppm and the OSHA permissible level of 50 ppm.

Silicates - Ten samples were collected on October 11 and analyzed for silicates. No silicates were detected in these samples. An additional 10 samples were collected on October 18; silicates were either not detected or were detected at levels below the NIOSH Recommended Exposure Limit (REL) time-weighted average of 0.05 mg/m3.

Direct Air Readings - Using portable monitors, direct air readings were taken in and around ground zero on Qctober 27 and Qctober 28. Several carbon monoxide readings were defected above the NAAQS 8-hour average of 9 ppm, during the early afternoon on Qctober 27 and during the late morning on Qctober 28. The readings were below the NAAQS 1-hour average of 35 ppm and the QSHA permissible level of 50 ppm.

Latest Available Daily Environmental Monitoring Summary

Resources on the World Wide Web:

US Department of Labor's Occupational Safety and Health Administration

New York City Department of Health — US Department of Health and Human Services New York State Emergency Management Office

EPA information about the events of September 11

2 of 3 11/2/2001 9:37 AM

CITY_21MC100_0 02416953

NYC-WTC_000287140

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000287140Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →