Airborne asbestos TEM analysis, Warren & [name]

Machine-extracted title · confidence 43%

TEM analysis of airborne asbestos for NYC DEP, client Warren & [name], project 29.

NYC-WTC_000283039
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

z ■< Z o o g O AIRBORNE ASBESTOS ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY I “0 o c o CT o A-rucMiC^ A CLIENT: Warren & Panzer Engineers, P.C. PROJECT: NYC DEP, 29 Park Row ro A I ntNIvA LABORATORY ID #: T02 11-089 o' oo DATE OF REPORT: 11/19/02 Ca5 "0 o ENVIROI««ENTAL SERVICES INC.ANALYT. METHODOLOGY: AHERA DATE OF ANALYSIS: 11/19/02 o Ca5 CD TeL (718) 784-7-WO FILTER TYPE: MCE EFFECTIVE FILTER AREA (mm^): 385 9L Fax. (718) 79^085 AVERAGE G.O. AREA (mm^): 0.013433 O o o c LABORATORY RESULTS 3 o 3 CLIENT # LAB. ID # LOCATION VOLUME G.O.’s AREA ANALYT. TOTAL TOTAL AIR AIR ASBEST. AMPHIB. (It) ANAL ANALY .SF.NSITIV. ASBESTOS ASBESTOS CONC. CONC. TYPE ASBEST YZED ZED (struct./cm'') AIR CONC. FILTER FOR FOR CHRYS. TYPE (mm^) (struc./cm’) CONC. STRUCT. STRUCT. SPECIFY (str./mm’) O.S<S<5pm S>5.0|im 01 IWA T02-11- IWA on roof center 1305 5 0.0672 0.0044 <0.0044 <14.89 NA NA~ NA NA 089-4155 ofWA 02IWA T02-11- IWA on roof west 1305 5 0.0672 0.0044 <0.0044 <14.89 NA NA NA NA • 089-4156 section of WA I 03IWA T02-11- IWA on roof east 1305 5 0.0672 0.0044 <0.0044 <14.89 NA NA NA NA 089-4157 section of WA 04IWA T02-11- IWA on roof 10ft 1305 5 0.0672 0.0044 <0.0044 <14.89 NA NA NA NA 089-4158 away of door entrance of roof 05OWA T02-11- OWA on stair well 1305 5 0.0672 0.0044 <0.0044 <14.89 NA NA NA NA 089-4159 leading to roof 1ft of door entrance to roof

ANALYST LABORATORY DIRECTOR E. Sioukri Spiro Dongaris o LABORATORY CERTIFICATION NUMBERS: NVLAP 101958, ELAP 10955 K I Athenica Environmental Services Ine. (AES), is responsible only for infoimation pertaining to samples taken by its employees. S Air sampling cassettes will be stored for sixty (60) days. AE.S Inc . should be notified within this time frame for a true duplicate analysis. o If AES Inc., did not conduct the sampling, the reported airborne concentration was derived based on information provided by the client. Under these circumstances, the air concentration data is o ..upplied solely for the convenience of the client. o I he report relates only to items tested. This report must not be used to claim product endorsement by NVLAP or any other agency of the U.S Government. Test reports may not be reproduced I except in full and with prior approval of AES Inc o o I he liability of Athenica Environmental Services Inc. with respect to the sen ices charged, .shall in no event exceed the amount of the invoice.

<75

on CO on

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000283039Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →