NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 1 page

Airborne asbestos analysis, NYC DEP lab, Feb 2003

Machine-extracted title · confidence 42%

Transmission electron microscopy asbestos analysis report for NYC DEP project, facility sample.

NYC-WTC_000282863
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

AIRBORNE ASBESTOS ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY i-M A CLIENT: Warren & Panzer Engineers, P. C. PROJECT; NYC DEP, 15 Park Row ATHENICA LABORATORY ID #: T03-02-011 DATE OF REPORT: 02/04/03 ENVIRONMENTAL SERVK ES IN(. ANALYT. METHODOLOGY: AHERA DATE OF ANALYSIS: 02/04/03 Tel (718)784-7490 FILTER TYPE; M C E. EFFECTIVE FILTER AREA 385 Fax (718) 784-4085 AVERAGE G.O. AREA (mm’): 0 012820

LABORATORY RESULTS

CLIENT # LAB. ID # LOCATION VOLUME G.O.’s AREA ANALYT. rOTAL TOTAL AIR AIR ASBEST. AMPHIB. (It) ANAL ANALY SENSITIV. ASBESTOS ASBESTOS CONC. CONC. TYPE ASBEST YZED ZED (striict./cm’) AIR CONC. FILTER FOR FOR CHRYS. TYPE (mm’) (struc./cm^) CONC. STRUCT. STRUCT. SPECIFY (str./mm’) 0.5<S<5pm SSS.Opm 01 T03-02- East side of roof 1740 4 0.0513 0.0043 <0.0043 <19.50 NA NA NA NA 011-171 02 T03-02- East side of roof 1728 4 0.0513 0,0043 <0.0043 <19.50 NA NA NA NA 011-172 03 T03-02- 10'" floor east side 1700 4 0.0513 0.0044 <0.0044 <19.50 NA NA NA NA 011-173 04 T03-02- 1 o'" floor east side 1692 4 0.0513 0.0044 <0.0044 <19.50 NA NA NA NA 011-174 05 T03-02- 1 o'" floor east side 1688 4 0.0513 0.0044 <0.0044 <19.50 NA NA NA NA 011-175

ANALYST LABORATORY DIRECTOR E. Sioukri Spiro Dongaris

LABORATORY CERTIFICATION NUMBERS: NVLAP 101958, ELAP 10955

Athenica Eiivironmentai Services Inc, (AE.S), is responsible only for informalion pertaining to samples taken by its employees. Air sampling cassettes will be stored for sixty (60) days, AES Inc., should be notified within this time frame for a true duplicate analysis. o If AES Inc,, did not conduct the sampling, the reported airborne concentration was derived based on information provided by the client. Under these circumstances, the air concentration data is H supplied solely for the convenience of the client. K The report relates only to items tested This report must not be used to claim product endorsement by NVLAP or any other agency of the U.S. Government. Test reports may not be reproduced I to except in full and with prior approval of AES Inc. S the liability of Athenica Environmental Services Inc. with respect to the services charged, shall in no event exceed the amount of the invoice. o o o I o o to CD O', US. CO CD to

NYC-WTC_000282863

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000282863Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →