NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 8 pages

Dust wipe analysis, 114 Liberty Street, 2003

Machine-extracted title · confidence 57%

Summary of lead/dust wipe analysis from 114 Liberty Street site samples.

NYC-WTC_000282569–000282576
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

JLC ENVIRONMENTAL CONSULTANTS. INC. 200 Park Avenue South, Suite 1001, New York, New York 10003 Phone: (212) 420-8119 Fax: (212) 420-6092 Protect No.: 03-2744 New York City D.E.P, ELAP Lab Code: 11029 Analyte: LEAD/ WIPE 59-17 Juncaon Blvd. N OSH and AIHA Lab Code; 100273 bate Collected 3/29/2003 FlUBhino.NY 11373 NVLAP Lab Code; 101983 Date Received: 3/30/2003 Date Analyzed; 3/30/2003 Batch «; 0303L410

Site; 114 Liberty Street, 12th Floor, New York, NY

SUMMARY OF ANALYTICAL RESULTS - DUST WIFE

Sample# Description/ Location Area in Inches Lead Lab# (LxW) Concentration Cllent'9 Sample (u9/n2)

21 Lead Wipe/ 6th Floor/ South East Bathroom/ North Wali/ 12x12 <9 3432 Lower Left 21

22 Lead Wipe/ Sth Floor/ Hallway/ Floor 12x12 <9 3433 22

23 Lead Wipe/ Sth Floor/ Kitchen/ Counter Top 12x12 <9 3434 23

24 Lead Wipe/ 5th Floor/ South East Bathroom/ North Wall/ 12x12 <9 3435 Lower Left 24

Semple Analysis Bv: Atomic Absorption Spectrometry (AAS) using an alr-acetylene flame with background correction. Method of Sample Preparation and Analysis All samplee were prepared and analyzed in accordance with the HUD 'Guidelines for the Evaluation and Control of Lead Based Paint Hazardous in Hpuelng" Appendix 14.2 and the Environmental Protection Agency Method EPA SWS49-3050/7420.

Gulem Machhiwala Collected By; Peter Koslowsky Laboratory Director Analysed By; Madell Collins

Minimum Dectecaon Limit - <20 us4t2 HUO "Ouidelines fa- tha Eva uation and Control of Lead-Based Paint Hazardous In Housing* 00/98; define the clearance standards, based on wipe sampling are: *40 ug/ft2 for floors; *250 ug/ft2 for Interior window sills; ‘400 ug/ft2 for window and exterior concrete or other rough

Page 6 of 9

U/8 'd 952 'ON dt/iNdWNOdlANi 31 r

CITY_DEP_WORBY_CANNATA_SUBP_000006043

NYC-WTC_000282574

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000282574Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →