NYC-WTC_000278003
SciLab PCM fiber results; sample data, liters, and fiber counts.
1 shared non-person entities · 1 shared topics · similarity 0.981
machine-extracted · confidence unavailable · Check page ↗Microscopy (PCM) fiber results with sample metrics dated 10/1998.
NYC-WTC_000278052–000278054OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
SciLabjob#: 98-10*5948 Client Name: Applied Technology Services, Inc.
s Phase Contrast Microscopy (PCM) Fiber Results A98I13; FitterraanHaU NYC, NY CL Flow Air Fiber Fibers SciUb CItenl _Dale Rale Duration Fields Fibers Density, Cone. TWA Sample * Saropie ff / Location LDiiecled (Liters/min.) (min.) (liters) (Fibers/mm^ ) (FibersAx)
32 02 101098 51 10/10/98 14 90 1260 100 2 2.55 < 0 002 pM3 FIN/13t>i Floor W. Side nj 33 02 101098 52 10/10/98 14 90 1260 100 2 2.55 < 0.002 vN ry RN/Uth Roor In the Middle 34 02 101098 53 10/10/98 0 0 0 100 0 5 0.64 HN/Field Blank Footnotes: /
35 02 101098 54 10/10/98 0 0 0 too 0.5 0.64 FIN/Field Blank Footnotes: /
36 02 101098 55 10/10/98 0 0 0 100 0.5 0.64 FIN/Field Blank Footnotes: / 37 02 101098 56 10/10/98 0 0 0 100 0.5 0.64 FIN/Field Blank Footnotes: /
38 02 101098 57 10/10/98 0 0 0 lOO 0.5 0.64 FIN/Field Blank Footnotes: /
8 39 FIN/Field Blank 02 I0I098 58 10/10/98 0 0 0 100 0 5 064 Footnotes: / (J iZ Reporting Notes: (■) Rbers/cc carioor be calculated for sanies (or blanks) wi^ no air volume Analyzed by: Red Corirossi CzA '_>< 1 Dale Analyzed: 1Q/12A/8 a Samples analyzed by NIOSH 74D0(A) MdttlOD' Issne 02.8/15/94; Limit of Detection ■ 5.5 fibers per 100 fields or 7 fibers / mm2; This report relates ONLY to the sample analysis expressed as fiben/sq mm of filter area; ND » no Obers observed; NA » Not Analyzed; Walton - BeckeU gradicult field area 0.00785 «nin2; Duralion in minules; TWA = 8Hr TWA calculsiion ussuraes zero exposure for remainder of 8 hour period ml sampled; Upper 95% Conridcmx Limit (Employer’s Complianoe Testi - CaAculatod as a one sided UCL to determine 95% ccnainty of compliance witb the aOl fiber/cc standard; Estimated relative standard deviation; Iniralab St = 0.270, Inteilab Sr « 0 450. ELAP *11480
CD 0-^
O
to S IS v-4 I o (>J o 1 o I o 8 o co
o co wo
NYC-WTC_000278054
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000278003
SciLab PCM fiber results; sample data, liters, and fiber counts.
1 shared non-person entities · 1 shared topics · similarity 0.981
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000186295
Laboratory report documenting PCM fiber analysis results for air samples collected in October 1998.
2 shared non-person entities · 1 shared topics · similarity 0.979
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000186291
Laboratory report documenting PCM fiber analysis results for air samples collected in August 1998.
2 shared non-person entities · 1 shared topics · similarity 0.977
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000277979
PCM fiber results; 8/12/98 samples with fiber measurements.
2 shared non-person entities · 1 shared topics · similarity 0.977
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000278009
Microscopy fiber results with sample collection data and duration for 8th Floor FINALS.
2 shared non-person entities · 1 shared topics · similarity 0.976
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000278007
Fiber analysis results from Microscopy (PCM) on samples processed for [name] Services, Inc.
2 shared non-person entities · 1 shared topics · similarity 0.974
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000278015
PCM fiber results with sample times, volumes, and fiber density measurements.
2 shared non-person entities · 1 shared topics · similarity 0.973
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000195951
Laboratory report presenting PCM microscopy fiber counts for samples collected on January 8, 1997.
1 shared non-person entities · 1 shared topics · similarity 0.973
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000278017
PCM fiber results with fiber counts per sample and decon steps.
2 shared non-person entities · 1 shared topics · similarity 0.973
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000186285
Laboratory report documenting PCM fiber analysis results for air samples collected on August 11, 1998.
2 shared non-person entities · 1 shared topics · similarity 0.973
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000277976
SciLab PCM fiber results for 3rd floor, August 1998, fiber counts.
2 shared non-person entities · 1 shared topics · similarity 0.973
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000278034
PCM fiber results with 2 samples and fiber counts, Broadway location.
2 shared non-person entities · 1 shared topics · similarity 0.972
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000277963
Fiber results for 1st Floor NE; includes density and fiber counts.
Similarity score 0.984 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000277961
SciLab PCM fiber results for 29 092497 01; duration and air data.
Similarity score 0.983 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000278019
Fiber results per sample with counts and flow details.
Similarity score 0.983 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000278017
PCM fiber results with fiber counts per sample and decon steps.
Similarity score 0.983 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000186295
Laboratory report documenting PCM fiber analysis results for air samples collected in October 1998.
Similarity score 0.982 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000277954
PCM fiber results with sample 29091697-01; 9/16/97 measurements.
Similarity score 0.981 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000278003
SciLab PCM fiber results; sample data, liters, and fiber counts.
Similar indexed content
NYC-WTC_000186295
Laboratory report documenting PCM fiber analysis results for air samples collected in October 1998.
Similar indexed content
NYC-WTC_000186291
Laboratory report documenting PCM fiber analysis results for air samples collected in August 1998.
Similar indexed content
NYC-WTC_000277979
PCM fiber results; 8/12/98 samples with fiber measurements.
Similar indexed content
NYC-WTC_000278009
Microscopy fiber results with sample collection data and duration for 8th Floor FINALS.
Similar indexed content