Lab report: PCM fiber results, 8th Floor FINALS, 1998

Machine-extracted title · confidence 20%

Microscopy fiber results with sample collection data and duration for 8th Floor FINALS.

NYC-WTC_000278009–000278010
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

( f SciLabJoo#; 98-08-7191 Client Name; Applied Technolo©' Services. Inc. Phase Contrast Microscopy (PCMl Fiber Results A98113; Sth Floor; FINALS Q. Flow Air Fiber Fibers SciLab Client Rate Duration Filtered Fields Fibers Dcnsit) Cone. TWA Sample * Sample W / Location Oillected (hicrs/min.) (min.) (lileis) (Fibers/mm ) (Fibersfee) K cn 16 29.08.24.98-30 t/24/98 15 80 1200 100 3 3.82 < 0.002 p kO FIN - Sth n Tent »11 on Greenwich Side ISWA ru 17 29.08.24.98-31 8724/78 IS 80 >200 100 3 3.82 < 0.002 fu FIN - 8lh Fl. Tent«12 Oieenwich Side ISWA 18 29.08.24.98-32 8/24/98 15 80 1200 100 2 2 55 < 0.002 FIN - 8th Fl. Tert e 13 Greenwich Side ISWA 19 29.08.24.98-33 8/24/98 IS 80 1200 100 4 5.10 < 0 002 FIN - 8th Fl. Tert 814 Greenwich Side ISWA 20 29 08.24.98-34 8/24/98 15 80 1200 too 2 2.55 < 0 002 FIN - 8lh n. Tert 815 Greenwich Side ISWA 21 29 08.24.98-35 8/24/98 0 0 0 too 0 5 0.64 Field Blank PoolDOlei: I 22 29.08.24.98-36 8/24/98 0 0 0 100 0.5 0.64 Field Blank Pootnnlej: / Reporting Notes: (1) Tibers/cc cannot be calculated fc Its (or bl aiiks) with no *ir volume. Analyzed by: Fred Corirossi ; Date Analyzed 8/24/98 Samples analyzed by NIOSH 7400(aVmETHOD, Issue <<2. 8/15/94; Limit of Detection - 5.5 fibers per 100 fields or 7 fibers / mm2; This report relates ONLY Io the sample analysis expressed as fibers/sq mm of filler area; MD ’ no fibers observed; NA = Not Analyzed; Walton - Beckett giadicule field area 0 00785 mm2; Duration in minutes; TWA = 8Hr TWA calculation asmmes 5 s zero exposure for letnainder of 8 hour period not sampled; Upper 95% Confidence Limit (Employer's Compliance Test) - Calculated as a one sided UCL to determine 95% cerlaint)' of compliance with the 0.01 fiber/cc standard; Estimated relative standard deviation: Intralab Sr = 0.270, Inlerlab Sr * 0.450. ELAP #11480

o H Ri N) n sH I

o OJ

1^ o o CaJ J o o co '.O

NYC-WTC_000278010

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000278010Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →