NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 1 page

Lab report, PCM fiber results, 29 Aug 1997

Machine-extracted title · confidence 41%

PCM fiber results with flow, air, and fiber counts for sample location BKO-1.

NYC-WTC_000277948
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

<

Job#: 08-97-6422 ( Maine; Applied Technology Services, Inc, Phase Contrast Microscopy (PCM) Fiber Results A97 195 r. Flow ,, Air Fiber Fibers Client Dale _ Duration Density Cone. TWA Collected ***. . (min.) Filtered Fields Fibers Sample # / Location (hters/inin.) (lilersl (Fibers/mm ) (Fibcrs/cc) 29 081997 01 8/19/97 15 80 1200 100 13 16.56 0,005 BKO-1 JI Floor North East Comer Of Aiea ISWA 29 081997 02 8/19/97 IS SO 1200 100 13 16 56 0.005 BKO-lil Floor North Middle Of Area ISWA 29 081997 03 8/19/97 15 80 1200 100 3 3.82 < 0 002 BKO-ltt Floor North West Cotner Of Area ISWA 29 081997 04 8/19/97 15 80 1200 100 7 8.92 0.003 BKG Isi Floor Between Nonb East Comer Of Middle Of Aic» ISWA 29 081997 05 8/19/97 15 80 1200 too 8 10.19 0.003 BRG-lst Floor Between North West Comer /Vid Middle Of Area ISWA 29 081997 06 8/19/97 15 80 1200 too 8 10 19 0.003 BKO isi Floor West North Corner Of Area ISWA 29 081997 07 8/19/97 1.5 80 1200 100 3 3.82 < 0.002 BKO-1 SI Floor West Middle Of Area ISWA 29 081997 08 8/19/97 15 SO 1200 100 2 2.55 < 0 002 BKGlu Floor By Bathroom West Of Area ISWA .rting Note*: /yy, tnatyzed by; Marvin Brothers I " \ __________ Pal- Analyzed: H21t91 HLAP 8 11480 Jampies analysed by NIOSH 7400(A) METHOD. Issue #2. 8/15/94; Limit of Detection = 5.5 fibers per IfiO fields or 7 fibets / ii«ii2; TWt re port relates ONLY to the sample analyris expressed IS fibeia/sq mm of filter area; ND «= no fibert observed; NA = Noi Analyzed; Walton - Beckett pradiciile field area 0.00785 tnro2; Duration in minutes; TWA = 8llr TWA cakiilaiton assumes reto exposure for innainder of 8 hour period not tampled; Upper 95% Confidence Limit (employer's Compliance Test) - Calculated as a one tided UCI. to determine 95% certainty of compliance with the 0.01 fiber/cc standard; Estimated relative standard deviation: Intralab Sr » 0.270, Inletlab Sr «= 0.450. Phate Contrast Microscope; Olympus, Model CII-2. o M I**’

s fk)

o

o

o its.

NYC-WTC_OOO277948

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000277948Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

PCM fiber results, BM.. 30W

NYC-WTC_000304680

PCM fiber results with sample and fiber concentration data for site 30W.

Similar indexed content

Compare copies and versions →