CBIRF respirator study draft, FDNY

Machine-extracted title · confidence 38%

Continued draft pages of respirator device study; content about protection levels.

NYC-WTC_000277520–000277532
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Material and methods

The equipment used was an FPBR (Fan-supplied Positive pressure Breath responsive Respirator) model SE400AT with a Domestic Preparedness Filter (ABEK3P4). This filter is designed to filter ail known war-gases, TIGs (Toxic Industrial Gases) and particulates including biological and radioactive particulates. The respirator has a built-in flow meter that is based on the pressure-drop on a known restriction. The data is collected by a data logger at 50 Hz on two channels (pressure in the ori-nasal mask and flow, including the volume of air passing through the respirator). The SE400AT used are identical to the NIOSH approved units, only calibrated according to Attachment 1. For this report only the volume of air (minute liters) and the PIAF (liters/minute) are used. The heart rate was measured with Polar Electro heart rate meter (S610). All data was transferred to a computer for analysis.

Subjects Forty-five marines (42 male and 3 female) participated in the study. Anthropometric details are given in table 1. Table 1 Average Standard Min Max All Subjects deviation Age 2 19 29 Weight kg 11 5’9 105 Height cm 181 9 152 191

Test Procedures The test was carried out at US Marine Corps training facility (Indian Heads) on September 20, 2002. The weather was sunny, temperature +22 +2 degrees Celsius, relative humidity 75%. The subjects were dressed in military training uniforms including military boots. They were also wearing a 22.7 kg lead vest during the entire exercise, as well as the SE400AT respirator and data logger (3.62 kg). A short introduction to the SE400AT was conducted before the test. The test subjects were then helped to get dressed, and to start the data logging. The protocol was the same ‘Agility Test’ as that used as a requirement for a fire-fighter to join the brigade. Normally the subjects need to complete the test in a specific time (10 minutes 20 seconds). However, this time requirement did not apply to this test. The time spread was 12 to 20 minutes. The Agility Test protocol includes the following elements: #1 — Stair climb, wearing an extra 22.7 kg lead vest, 3 minutes #2 — Hose drag, 1min #3 — Carry equipment, 1 min #4 — Raise a ladder, Imin #5 — Forced entry (hitting a wall with a certain force with a sledge hammer), 1 min #6 — Search (crawling through a maze) 3 min #7 — Rescue (pulling a stretcher with a mannequin [80 Kg] a certain distance), 1 min #8 — Ceiling breach & pull down (opening and closing a smoke hatch a number of times), 1.5 min

The SEA Group Goran Berndtsson Page 2 27/11/2002

CITY_21MC100_007398338

NYC-WTC_000277521

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000277521Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

CBIRF respirator study draft forms, FDNY

NYC-WTC_000277507

Forms related to a survey on respirator devices and protection for US Marine personnel; authorization and setup content.

Similar indexed content

CBIRF respirator study draft, FDNY

NYC-WTC_000277533

Draft materials of respirator study commissioned by CBIRF; focus on negative pressure respirators and PAPRs.

Similar indexed content

Compare copies and versions →