acknowledge that their conclusions might have been skewed because the dust they tested was already several months old.

“By November, outdoor dust contamination was likely reduced by wind, rain, and cleaning (city workers vacuumed the streets and sidewalks with HEPA trucks). Indoor settled surface dust may have been reduced if areas were cleaned before being sampled. Therefore, these results probably underestimate the levels of World Trade Center-related materials that were in lower Manhattan immediately after September 11,” they wrote.

Plus, the contaminants were not uniformly dispersed—so that one could find high levels of certain pollutants in one area and not in another. They were heterogeneous, random mixtures of everything in the buildings—plastics from furniture, mercury from lightbulbs, including exotic metals like vanadium from computer parts.

The ATSDR wrote, for example, “A review of the building sampling results from this investigation indicates that there is not a consistent spatial distribution pattern of asbestos, SVF, mineral components of concrete, and mineral components of wallboard in air and settled surface dust. This indicates that the materials are heterogeneously distributed.”

A key problem was that the teams of people and the tools for environmental monitoring were not in place to respond to an event like that which happened. Shockingly, even though the high particulate count from the building collapses was higher than New York City had ever experienced in its history, the tragic event violated no pollution standards for particulate matter.

That’s because the air quality regulations were set up to measure particulate matter loadings over 24 hour periods, rather than intense, short term bursts. Yet such a high- particulate storm, even lasting several hours, “can produce significant adverse health impacts,” wrote Eric Goldstein et. al. in the NRDC’s paper, “The Environmental Impacts of the World Trade Center Attacks.” Plus, these authors note, the same air standards did not adequately account for other health concerns arising from very fine particulate matter arising from the fires.

“We in the environmental health community are used to high probability events with low probability risks,” says Paul Lioy, “the effects of ubiquitous, low level toxic substances, their probability of giving people cancer over a 70 year lifetime. We were not equipped to deal with a low probability event with high probability consequences.”

Interior environments

A significant vacuum here was that the agencies didn’t address the hazards right under people’s noses - in interior spaces - as Rep. Jerrold Nadler would charge in congressional hearings months later.

CITY_21MC100_012173414

NYC-WTC_000277111

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000277111Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →