NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 1 page

Table of rankings, pre-test concentrations, MMVF

Machine-extracted title · confidence 45%

Table 8: ranking of contaminants by pre-test concentrations and belongings.

NYC-WTC_000276773
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

< c Internal Review Draft <

Table 8. Ranking of Residential Units by Pre-Cleaning Average Concentrations of Several Contaminates Observable Cleaning Times Asbestos Lead MMVF Sum of Unit Number Presence of Belongings* Dust Test Cleaned Wipe Microvac Wipe Ranks Rank Rank: Rank Rank 5C significant 3A,3A,3B 3 no, 1 couch 3 3 1 6 11 5A minimal 3B,3B 2 no, 1 couch 1 1 12 4 18 3C significant 1A,1A,3B 3 no, 1 couch 4 2 3 9 18 3D significant 1A,1A 2 no, 1 couch & chair 2 5 6 7 20 4D significant 2A,2A 2 no, 1 chair & ottoman 9 6 4 3 22 4C significant lA 1 no, 1 couch 7 4 2 10 23 2B minimal 3A 1 no, 1 couch 5 7 24 2A minimal IB,IB 2 no, 1 couch & chair 6 8 7 5 26 5D significant 3B 1 no, 1 couch 8 10 5 11 24 3B minimal Scope A 2 _______ yes_______ 11 12 9 2 24 3A minimal 2B 1 yes, carpet 10 9 8 8 35 4A minimal 2A,2A 2 no, 1 couch 12 11 10 12 45

Each contaminant per sampling type was ranked based upon the average concentration per unit with the highest average concentration receiving a rank of 1 and the remaining values continued in ascending order up to 12. The ranking for each combination was then summed for each unit to determine which unit had the highest overall concentration of contaminants. The sum of the rankings for each compound per unit indicates that 5C and 5 A contained the highest concentrations of contaminants prior to cleaning. Note that the lower the sum of ranks, the higher the concentration of total contaminants.

Note that Unit 4B is not included in the list of rankings because there were no lead microvac samples collected in this unit. As a point of reference, the sum of the ranks for 4B for the asbestos, lead, and MMVF wipe samples totals 27. This indicates that this unit would have placed in the bottom-tier of the rankings. *Note in units that retained personal belongings the items were cleaned and bagged, thereby creating a situation where no belongings were present. Cleaning Equipment Description o lA Basic w/o AFD H 2A Intermediate w/HEPA w/o AFD 3A Advanced w/o AFD I—i s o IB Basic w/AFD 2B Intermediate w/HEPA w/AFD o o 3B Advanced w/AFD Io

o

(JI

NYC-WTC_000276773

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000276773Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →