NYC 9/11 Public Portal Document
Table 4. Lead
Tier Action Lead (settled dust) Lead (indoor air)
Level Basis Level Basis
I Aggressive >40 ug/ft^ 1) HUD standard >1.5 ug/m" NAAQS
cleaning. If levels for floors (intended to
persist, take 2) Residential keep 99.5% of
additional action to Lead Hazard children below
reduce exposure. Standard (TSCA 30 ug/dl)
Section 403)
II Maintain 40 ug/f? to 25 25 ug/tf is HUD 1.5 ug/m’ to 1 ug/m’ is the
recommended ug/f? (or screening level 1 ug/m’ (or calculated value
cleaning methods. background) for floors background) using EPA’s
Consider additional lEUBK Lead
monitoring. Model for
Children*
III No further action <25 ug/tf (or Level could also 1 ug/m’ (or Level could also
background) be set at that background) be set at that
found in found in
background, or background, or
unaffected, areas, unaffected,
so that no areas, so that no
increase in risk increase in risk
due to lead due to lead
would be would be
expected. expected.
* EPA developed the Integrated Exposure Uptake Biokinetic (lEUBK) Lead Model [EPA, 1994]
to evaluate multimedia lead exposure to children in residential settings. EPA established a goal
of attaining a 95% probability that blood lead levels in children be less than 10 ug/dl [EPA
1994a]. Setting the indoor air lead concentration at 1 ug/m^ (and using background
concentrations for lead in water, diet, soil and dust) the lEUBK Lead Model estimates that 96%
of the blood lead probability distribution falls below 10 ug/dl. See Appendix E for model run
data files and graph of blood lead probability distribution.
17
CITY_21MC100_011109189
NYC-WTC_000276629
OCR can misread numbers and units. Confirm readings against the page image before using them.
NYC-WTC_000276629Source: NYC Law Department, mirrored locally