NYC-WTC_000242989
COPC committee reporting contributors for WTC-related contaminant list.
39 shared non-person entities · 1 shared topics · similarity 0.977
machine-extracted · confidence unavailable · Check page ↗EPA/NCEA draft on exposure and [name] evaluation relating to World Trade Center.
NYC-WTC_000276455–000276612OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
IV.d. Dioxin
Dioxin-like compounds (referred to also in discussions below simply as “dioxins”) are formed during combustion, and it is expected that production of these compounds would have resulted from the initial impact and ensuing fires at the WTC. Dioxin-like compounds may be formed in other ways as well, such as in the chlorine bleaching process for paper products or in the manufacturing process for certain chlorinated organic chemicals. However, uncontrolled or improperly controlled combustion appears to be the major source of new emissions (EPA, 2000). A total of 30 compounds are considered to be “dioxin-like”: 7 polychlorinated dibenzo-p-dioxins (abbreviated dioxins), 10 polychlorinated dibenzofurans (furans), and 13 coplanar PCBs. These individual compounds are called “congeners.” Measurements at the WTC included only the 17 polychlorinated dioxin and furan congeners, not the PCB congeners (total PCBs were measured, as discussed above). Because dioxin-like compounds are present at minute quantities, concentrations in this section will be described in terms of picograms per cubic meter (pg/m’).
Concentrations of dioxin-like congeners are expressed on a toxic equivalent, or TEQ basis. A TEQ concentration is calculated as the sum of the toxically equivalent concentrations of each of the 17 congeners. A congener’s TEQ concentration is calculated as its concentration (C^) times its toxicity equivalency factor, or TEFj. TEF values are equal to 1.0 or less, and relate the toxicity of 16 of the 17 congeners to the most toxic congener, 2,3,7,8-TCDD (the 17* congener naturally assigned a TEF of 1.0). An overall TEQ concentration is, therefore, S(TFF *C,). When a congener was not detected in the sample, a value of one-half the detection limit was used for that congener in calculating the TEQ concentration. This is the traditional approach to calculating a TEQ concentration when some of the congeners are not detected and others are; alternate approaches include assigning either 0 or the detection limit to the congeners that are not detected.
The TEQ concentrations on the WTC web site were developed using the “International” set of TEF values (I-TEF; EPA, 1989). In 1998, the World Health Organization proposed a new set of TEF values (WHO-TEF; Van den Berg, 1998). The principal change relevant to quantifying the TEQ concentration of a mixture comprised of the 17 dioxin and furan congeners is that the TEF for the penta dioxin-like congener, 1,2,3,7,8-PCDD, has been increased from 0.5 to 1.0. The other change of less impact to calculating the TEQ concentration is that the TEF values of the two octa congeners, OCDD and OCDF, were reduced from 0.001 to 0.0001. Since the penta congener occurs in most samples, the net effect of this change is to increase the TEQ concentration slightly, in the range of 5-10%, depending on the prevalence of 1,2,3,7,8-PCDD in the sample. For example, on the sample taken fi-om the WTC Building 5 monitor on September 23, when the I-TEQ concentration was 161 pg TEQ/m\ the 1,2,3,7,8-PCDD concentration was 40.8 pg/m\ In the I-TEF scheme, this contributes 20.4 pg/m\ but in the WHO-TEF scheme, this would add 40.8 pg/m^ to the final TEQ concentration. Therefore, the measurement of 161 pg TEQ/m’ would increase to 181 pg TEQ/m’ when switching to the WHO-TEF scheme, an increase of about 12%. An examination of the data shows that other I-TEQ concentrations would also increase, some by less than 5%.
This assessment uses the I-TEQ concentrations presented on the EPA WTC web site. Converting to WHO-TEQ concentrations would make a small and insignificant change to the
DRAFT-DO NOT QUOTE OR CITE 73 October 2002
CITY_21MC100_011109088
NYC-WTC_000276542
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000242989
COPC committee reporting contributors for WTC-related contaminant list.
39 shared non-person entities · 1 shared topics · similarity 0.977
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000319976
Contributors list for COPC committee on contaminants at World Trade Center site.
41 shared non-person entities · 1 shared topics · similarity 0.976
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000263437
SIA#14 draft report prepared for EPA Office of Emergency/Remedial Response.
34 shared non-person entities · 1 shared topics · similarity 0.975
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000250638
Draft EPA SIA#14 report on environmental data for World Trade Center site.
35 shared non-person entities · 1 shared topics · similarity 0.975
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000242900
Draft section describing selection of contaminants of potential concern.
40 shared non-person entities · 1 shared topics · similarity 0.974
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000303012
EPA audit report for World Trade Center environmental data, Nov 2001
34 shared non-person entities · 1 shared topics · similarity 0.974
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000320385
Oldraft report for World Trade Center background study prepared for FEMA, EPA Region 2.
46 shared non-person entities · 1 shared topics · similarity 0.974
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000321003
World Trade Center response air monitoring data overview describing EPA data collection.
20 shared non-person entities · 1 shared topics · similarity 0.974
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000148952
Data table listing specific street locations outside the World Trade Center site where volatile organic compound sampling was conducted.
90 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000348699
COPC committee report with contributors from EPA, NYC DEP, and state agencies.
41 shared non-person entities · 1 shared topics · similarity 0.979
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000348649
COPC committee report on World Trade Center contaminants with multi-agency authors.
39 shared non-person entities · 1 shared topics · similarity 0.978
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000162222
EPA staff distributed an environmental laboratory report to federal and city agencies on May 15, 2002.
27 shared non-person entities · 1 shared topics · similarity 0.975
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000148952
Data table listing specific street locations outside the World Trade Center site where volatile organic compound sampling was conducted.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000195194
Document excerpt acknowledging contributors and outlining the collaborative scope of an EPA environmental protection study regarding the World Trade Center site.
Similarity score 0.947 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000363060
Interim final report noting organizations involved and plan for third-party review.
Similarity score 0.944 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000145695
Form documenting the tracking and handling of environmental samples collected by the Department of Environmental Protection.
Similarity score 0.943 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000431857
EPA NYC Region 2 WTC response document, City data file.
Similarity score 0.943 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000148952
Data table listing specific street locations outside the World Trade Center site where volatile organic compound sampling was conducted.
Similarity score 0.943 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
Data table listing specific street locations outside the World Trade Center site where volatile organic compound sampling was conducted.
Similar indexed content
COPC committee report with contributors from EPA, NYC DEP, and state agencies.
Similar indexed content
COPC committee report on World Trade Center contaminants with multi-agency authors.
Similar indexed content
NYC-WTC_000242989
COPC committee reporting contributors for WTC-related contaminant list.
Similar indexed content
NYC-WTC_000319976
Contributors list for COPC committee on contaminants at World Trade Center site.
Similar indexed content