Exposure evaluation report, WTC site, Oct 2002

Machine-extracted title · confidence 55%

EPA/NCEA draft on exposure and [name] evaluation relating to World Trade Center.

NYC-WTC_000276455–000276612
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

antimony in mid-November at ORD Site K on the southwest perimeter of Ground Zero (but not at Sites A or C or at 290 Broadway to the north, northeast, or southeast of the WTC) suggests both a different source of WTC fire emissions and a likely climatic shift to winds flowing mainly tfom the north/northeast to the south/southwest. The chromium elevations seen around November 20, mainly at Site C, suggest possibly yet another later shift in the composition of Ground Zero sources of WTC-generated airborne particle emissions. Hence, the “WTC signature” appears to have varied over time in terms of its specific elemental composition.

In contrast to the above patterns of element levels which indicate that they may have originated from the WTC fires, the gradually increasing concentrations of nickel up to a range sustained during December and .January (after the WTC fires were out) seem to argue against any notable airborne fine-particle nickel emissions from the WTC fires subsequent to the collapse of the WTC buildings on September 11. Still, enrichments in samples of settled dust from sites east of the WTC (Lioy et al., 2002) are likely indicative of nickel having been among the metals present in high concentrations of airborne particles in the initial dust/smoke that enveloped lower Manhattan on September 11. This raises the possibility of (a) any remaining nickel-containing dust being re-entrained into outdoor air during later rescue/recovery operations and/or (b) continued elevations of nickel concentrations in WTC-derived indoor dust and re-entrained indoor air particles.

3. High Temporal Resolution Analyses The ORD PMj 5 and associated element measurements discussed above were obtained over sampling periods of close to 24 hours. Examination of additional data is necessary to determine more precisely the duration and nature of enhanced concentrations of PM constituents . if and to help understand possible public health impacts of such excursions. For example, of much interest are PM elemental composition data for the period October 3-5, when a high pressure system settled over New York during the early morning hours of October 3 and 4. Concentrations of sulfur were close to six times higher at the downwind ORD WTC site (Site A) than at the upwind site (Site K) on October 4. Concentrations of a number of other elements were also much higher by large enrichment factors at Site A as compared to Site K, as indicated by the enrichment factors (noted in parentheses) for the following elements: silicon (4IX), chlorine (500X), potassium (47X), calcium (5X), bromine (35OX), copper (BOX), zinc (I lOX), palladium (> lOOX), cadmium (>100X), antimony (>100X), and lead (66X). Overall, the above results are most consistent with brief, episodic increases from WTC Ground Zero during early morning hours on October 3 and 4 leading to elevated concentrations of PM and its constituent elements at WTC perimeter sites and one or another sites in lower Manhattan located downwind of the WTC on those days (i.e., to the north and/or northeast). These enhanced concentrations were superimposed on generally higher concentrations of PM and its constituents found upwind of the WTC on tliose days. The higher concentrations found at the upwind sites were associated with a high pressure system that settled over the New York Metropolitan Area during that period. In any case, the results suggest strongly that the WTC site was the dominant source of these elements on October 3-4.

University of California, Davis measurements (Cahill et al., 2002) on the roof of the DOE building indicate a sharp increase in concentrations of PVT mainly in the size range between 0.34 to 0.56 pm on the morning of October 3, as shown in Figure 19. This very brief excursion

DRAbT-JX) NOT QUOTE Oli CITE 35 October 2002

CITY_21MC100_011109049

NYC-WTC_000276503

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000276503Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000148952 · Box DEP Box 10

Data table listing specific street locations outside the World Trade Center site where volatile organic compound sampling was conducted.

Similar indexed content

NYC-WTC_000348699

COPC committee report with contributors from EPA, NYC DEP, and state agencies.

Similar indexed content

NYC-WTC_000348649

COPC committee report on World Trade Center contaminants with multi-agency authors.

Similar indexed content

Compare copies and versions →