been much higher than the lower limit given above, perhaps even approaching concentrations of condensed water vapor that are observed in dense fogs (i.e., thousands of pg/m^).

Thus, individuals engulfed in the initial dust/smoke cloud may have been exposed for several hours to concentrations of both fine and coarse inhalable particles anywhere in the range from milligrams per cubic meter (> 1,000 pg/m’) to perhaps hundreds of milligrams per cubic meter (> 100,000 pg/m^). However, it does not appear that people outside the lower Manhattan area (except possibly very briefly for those on Governor’s Island or in Brooklyn Heights) experienced such extreme PM exposures. This estimation is based, for example, on hourly PM- , levels observed at several NYSDEC monitoring sites (Figure 7) during September 11 to 13. Of most note, as seen in Figure 7, PM,, concentrations at NYC sites generally remained under 25 pg/m’ during most of September 11 and 12. However, hourly PM2 5 concentrations did increase to the 50-100 pg/m^ range for a few hours on September 12 and 13 at PS 64, which is located about 2.5 km northeast of Ground Zero, and at PS 199, which is located in Queens several miles east-northeast of Ground Zero. These PM2 5 increases most likely reflected east­ northeast dispersal of not only windblown fine PM from settled dust but also probably of newly formed fine PM generated by the intense fires (> 1000 °F) at WTC Ground Zero. This would be consistent with dispersal to the east-northeast of the WTC plume, as indicated by the ORD modeled trajectory plotted for September 13 (shown in Figure 8). The increased hourly PM, , levels at PS 64 and PS 199 (reaching 166 and 100 pg/m’ at 9 a.m. September 13) indicate that the WTC plume likely briefly fumigated the surface for a few hours at those and/or intervening locations during the morning of September 13.

Changes in wind direction later in the day on September 13 resulted in rotation of the WTC plume back to a flow predominantly to the south-southwest (mainly over New York Harbor) through September 14 and 15, as indicated in Figures 9 and 10. Note the very low PMjj hourly values (almost all < 6 pg/m’) at NYSDEC monitoring sites throughout the NYC area following rain associated with a frontal passage and, also, likely reflecting in part decreased vehicular traffic in the aftermath of September 11 events.

During the next several days, ORD plume dispersion modeling indicates that the plume rotated in such a manner as to result in transport in varying directions, including sometimes to the north-northwest (over northern New Jersey and NYC areas), but there was little indication of the plume fumigating the surface, based on surface PM measurements at preexisting PM monitoring sites. During the rest of September and on into October, 24-hour PM, 5 values at preexisting NYSDEC monitoring sites did not exceed the daily PM,, NAAQS (65 pg/m^ 24-h), In fact, daily PM2 5 values from most pre-existing fixed sites throughout the NYC area did not show marked elevations in comparison to historical PM, 5 levels for NYC areas, with the occurrence through mid- to late October (from time to time or from site to site) of a few 24-hour PM2 5 values approaching the 24-hour AQl LOC (40 pg/m^) not being notably out of line with past frequency of such excursions in NYC.

Starting September 21, the EPA/ORD WTC perimeter monitoring sites at Sites A, C, and K (within 100-200 meters of Ground Zero) allowed tracking of WTC-related ambient PM emissions in the immediate WTC vicinity. The ORD monitoring data, shown in Figure 11 (top) showed widely varying PM concentrations across the WTC perimeter sites from day to day, with

NOT QUOTE OR CITE 30 October 2002

CITY_21MC100_011109044

NYC-WTC_000276498

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000276498Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000148952 · Box DEP Box 10

Data table listing specific street locations outside the World Trade Center site where volatile organic compound sampling was conducted.

Similar indexed content

NYC-WTC_000348699

COPC committee report with contributors from EPA, NYC DEP, and state agencies.

Similar indexed content

NYC-WTC_000348649

COPC committee report on World Trade Center contaminants with multi-agency authors.

Similar indexed content

Compare copies and versions →