Exposure evaluation report, WTC site, Oct 2002

Machine-extracted title · confidence 55%

EPA/NCEA draft on exposure and [name] evaluation relating to World Trade Center.

NYC-WTC_000276455–000276612
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

The reported TEQ concentrations that were compromised due to high detection limits ranged in value from 0.5 to 5.0 pg TEQ/m\ which is about 5 to 50 times higher than normal urban background air concentrations. These measurements came from 9 specific air samplers which were located within Ground Zero (1 sampler) and near the WTC site (8 samplers). In general, the dioxin method’s detection limit is calculated by dividing the lowest mass of dioxin that the method can detect by the air that contained that amount, namely the air that flowed through the sampler. Thus, as more air is drawn through the sampler, the detection limit is lowered. These 9 air samplers operated for 8-hour periods, and drew in about 7 m^ of air. They began operation on September 23,2001.

Three other air samplers were operated for 72-hour periods, and drew in about 1000 m’ of air. These monitors were located several blocks from the perimeter of Ground Zero, and began operation on October 12. Because much more air was drawn into these samplers, the detection limits obtained for the dioxin-like compounds were lower, and TEQ concentrations could be routinely quantified as levels less than 1.0 pg TEQ/mT The first sampling events in October through November in these three monitors resulted in concentrations that were still elevated above typical background TEQ concentrations, at between 1 and 10 pg TEQ/m\ Starting at the beginning of December, 2001, and continuing through the termination of sampling in May of 2002, the measurements in these samplers decreased to levels that were mostly less than 0.10 pg TEQ/m^. More detail on these two sets of monitors (the 9 monitors sampling for 8 hours, and the 3 monitors sampling for 72 hours) is provided in Section IV.d below.

All the reported TEQ measurements from these 9 monitors for 2002, and the measurements from them in upwind conditions during 2001 (i.e., when the plume was moving in a direction opposite the monitors), were in this one-half detection limit range of 0.5 to 5.0 pg lTQ/m\ Thus, the ability to assess exposure during the early months of 2002, where there may have been elevations near Ground Zero as a result of cleanup activities, was compromised. Because the health risk from dioxin exposure is associated with accumulation of residues in body tissues, continued dioxin TEQ exposure within and near Ground Zero throughout 2002 could not be evaluated. The risk screening exercises conducted for dioxin were limited to the time period when the concentrations were highest and dioxin was detected. This issue is described in more detail in Section IV.d.

Asbestos: The large majority of outside air measurements ofasbestos were below established benchmarks and within the range of typical background levels. However, and similar to other contaminants, the few exceedences that were measured occurred near September I i in time and close in proximity to the WTC. Limited available evidence suggest the incursion ofasbestos to the indoor environment. A small study which sampled the indoor environment of two apartments on September J 8 showed very high indoor levels ofasbestos. A larger and more systematic study which sampled in November and December of2001 suggested that indoor levels of asbestos in dust were slightly higher near the WTC as compared to indoor levels in dust further away. Current efforts by the ERA focus on the measurement and clean-up of residential apartments near the WTC.

DKAn~D() NOT Q(/()TE ON CITE 8 October 2002

CITY_21MC100_011109021

NYC-WTC_000276475

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000276475Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000148952 · Box DEP Box 10

Data table listing specific street locations outside the World Trade Center site where volatile organic compound sampling was conducted.