PCM f/cc), respectively. W In a review of indoor air monitoring data from a variety of locations, arithmetic mean concentrations ranged from 3* 10’’ to 7*10’’ PCM f/cc. Levels of asbestos in 94 public buildings that contained asbestos ranged from ND to 0.2 TEM free (ND to 3* 10-3 PCM free), with an arithmetic mean concentration of 0.006 TEM f/cc (10-4 PCM f/cc). Analysis of data based on air samples from 198 buildings with asbestos-containing materials (ACM) indicated mean asbestos levels ranging from 4* 10"’ to 2.43* 10’’ TEM free (7* 10'^ to 4*1 O’’ PCM free).

Asbestos concentrations in 41 schools that contained asbestos ranged from ND to 0.1 TEM free (ND to 2*10 ’ PCM free), with an arithmetic mean of 0.03 TEM f/cc (5*10“* PCM free). Another study reported average concentrations of airborne asbestos fibers > 5 pm in length of 8*10’’ TEM f/cc and 2.2*10 “' TEM f/cc in 43 non-school buildings and 73 school buildings, respectively (the 60:1 conversion factors would not apply to these data, since the TEM readings were already on fibers >5 pm in width, so they are likely to be more directly comparable to PCM results). In another study in 71 U.S. schools, the mean, the 95 percentile, and the maximum asbestos levels were 1.7* 10 “*, 1.4* 10"’, and 2.3* 10 ’ PCM free, respectively.

A study of 49 buildings in the United States reported mean asbestos fiber levels of 9.9*1 O' “* PCM free in buildings with no ACM, 5.9*10'* PCM free in buildings with ACM in good condition, and 7,3*10'* PCM free in buildings with damaged ACM.

In general, concentrations of asbestos in both indoor and outdoor settings and in both rural and urban settings appears to be less than, and by some studies, sometimes substantially less than, 3*10 ’ free on a PCM volumetric basis.

lV.e.4. Asbestos Air Monitoring Data at the WTC Three sources of information were used to evaluate the asbestos air monitoring. One was the EPA WTC database itself. Downloads of this database occurred in May of 2002, and the data evaluated are current as of about mid-April, 2002. The WTC database includes measurements by several federal, state, and local agencies. The second source of data was the Trends Report dated May 16, 2002 (EPA, 2002a). There have been three Trend Reports. Generally, these reports obtain all their data from the EPA WTC database and provide summaries and interpretative analyses. The third source of data is a study commissioned by a “Ground Zero Elected Officials Task Force” to principally sample two apartments on September 18, 2001 (Chatfield and Kominsky, 2001). While the focus of that study was on the indoor environment (it is reviewed in more detail in Section V), two outdoor air samples were also taken.

The May Trends Report contains a summary of the PCM and TEM data collected between September 12, 2001 (the date of the first reported sample), and April 13, 2002, in the lower Manhattan area in the vicinity of Ground Zero. Additional TEM data from the Staten Island Landfill were obtained directly from the Region 2 WTC database. Figures 23 and 24 show the locations of fixed monitors at the Lower Manhattan and Staten Island Landfill areas,

DKAin'-!)O NOT Q[/OTE OR CITE 90 October 2002

CITY_21MC100_011109105

NYC-WTC_000276559

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000276559Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000148952 · Box DEP Box 10

Data table listing specific street locations outside the World Trade Center site where volatile organic compound sampling was conducted.

Similar indexed content

NYC-WTC_000348699

COPC committee report with contributors from EPA, NYC DEP, and state agencies.

Similar indexed content

NYC-WTC_000348649

COPC committee report on World Trade Center contaminants with multi-agency authors.

Similar indexed content

Compare copies and versions →