NYC-WTC_000318340
Office findings on EPA response to World Trade Center issues; August 2003.
48 shared non-person entities · 1 shared topics · similarity 0.955
machine-extracted · confidence unavailable · Check page ↗Document discussing lessons learned in children's environmental health related to Ground Zero sites.
NYC-WTC_000276036–000276449OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
SAMPLING AT PS150
Below is my synopsis of the test results available for PS 150 as of Thursday, December 6, 2001.
To sum it up: There was significant lead contamination in the school building, namely in “visible debris.” The internal area of the school was repeatedly cleaned. The most recent samples do not show the presence of lead in excess of the lead levels considered “acceptable.” Asbestos was present in dust sampled in September, but not in the air samples. Subsequent samples were conducted for air only - none showed the presence of asbestos. Indoor Air Quality samples were conducted on 4 consecutive days between Nov. 29 and Dec. 2. All samples showed levels below the thresholds applied by the consultant except for November 29, when respirable particulates were found above the EPA threshold both within and outside of the schooL Results from metal and hydrocarbon air sampling have yet to be submitted.
I. LEAD Standard: New York City Health Code part 173.14: (Final clearance after lead abatement has taken place is achieved when dust wipe samples indicate lead levels below those listed below) Window wells: 400 ^ig/sq.ft Windowsills 250 gg/sq.ft Floors: 40 fig/sq.ft
report, dated November 30,2001 Date of sampling: November 29. 2001 Out of 64 samples taken, 1 sample collected from floor and 5 sauries collected from window wells surfaces contain lead in dust above the guideline level of 40 gg/sq.ft and 400 gg/sq.ft, respectively. The dust samples found to contain lead above the guideline levels for floor and window wells were collected from the following locations (in parenthesis I put the “surface condition’’ entry from the chain of custody sheets; surfece condition refers to one of the following 3 categories: “visible dust”, “visible debris”, “no visible dust or debris”:
2™’ floor girl’s toilet - floor 103.2 p.g/sq.ft (no visible dust or debris) Room 501,2“’ window - window well 521.2 |xg/sq.ft (visible debris) Room 502 2“** window - window well 1,274.7 gg/sq.ft (visible debris) 3”^ floor corridor, 6* window - window well 1,627.8 gg/sq.ft (visible debris) Room 403,4* window - window well 947 gg/sq.ft (visible debris) 1^ floor foyer, 5* window - window well 1,570.4 gg/sq.ft (visible debris)
CITY_21MC100_012173155
NYC-WTC_000276310
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000318340
Office findings on EPA response to World Trade Center issues; August 2003.
48 shared non-person entities · 1 shared topics · similarity 0.955
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000319809
Document describing MS/PS 85M occupancy and recovery operations related to WTC.
33 shared non-person entities · similarity 0.953
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000278790
New York Council report on retrofitting HVAC systems at Ground Zero for IAQ.
36 shared non-person entities · 1 shared topics · similarity 0.961
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000106411
Union memorandum regarding environmental monitoring and cleanup protocols following the closure of Stuyvesant High School after the September 11 attacks.
13 shared non-person entities · 1 shared topics · similarity 0.960
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000322244
Consulting report cover page for HVAC retrofitting and air quality at Ground Zero.
28 shared non-person entities · 1 shared topics · similarity 0.959
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000144546
Internal memo directing DEP employees to preserve all records related to the World Trade Center attacks and subsequent environmental cleanup.
16 shared non-person entities · similarity 0.959
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000149798
Generic form or header page from the Department of Environmental Protection regarding general World Trade Center notices and requests.
39 shared non-person entities · 1 shared topics · similarity 0.958
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000453548
Board of Education disaster response summary for schools near WTC site.
27 shared non-person entities · 1 shared topics · similarity 0.957
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000144741
Standard administrative notice requiring the retention of original World Trade Center records as evidence for future legal actions.
34 shared non-person entities · 1 shared topics · similarity 0.955
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000153468
Page containing illegible text and a document identifier for the EPA Inspector General series.
14 shared non-person entities · 1 shared topics · similarity 0.955
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000145510
Notice from NYC Law Department instructing staff to preserve World Trade Center documents for potential legal actions.
48 shared non-person entities · 1 shared topics · similarity 0.954
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000138950
Draft excerpts of EPA OIG report for NYC interactions.
20 shared non-person entities · 1 shared topics · similarity 0.953
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000276455
EPA/NCEA draft on exposure and [name] evaluation relating to World Trade Center.
Similarity score 0.963 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000199886
Summary of initial and follow-up asbestos testing at PS 234 school, reporting dust and air sample results regarding fiber detection.
Similarity score 0.962 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000321465
ENVIRON evaluation of environmental data around PS 234, highlighting data collection and sampling context.
Similarity score 0.962 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000148952
Data table listing specific street locations outside the World Trade Center site where volatile organic compound sampling was conducted.
Similarity score 0.962 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000337662
Lab report on debris, soil and dust sampling around PS 234 with asbestos findings and abatement actions.
Similarity score 0.962 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000208402
Environmental consulting firm report detailing asbestos and lead sampling performed at the Gymnasium and adjacent areas of 199 Chambers Street on October 17, 2001.
Similarity score 0.959 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000278790
New York Council report on retrofitting HVAC systems at Ground Zero for IAQ.
Similar indexed content
Union memorandum regarding environmental monitoring and cleanup protocols following the closure of Stuyvesant High School after the September 11 attacks.
Similar indexed content
NYC-WTC_000322244
Consulting report cover page for HVAC retrofitting and air quality at Ground Zero.
Similar indexed content
NYC-WTC_000144546
Internal memo directing DEP employees to preserve all records related to the World Trade Center attacks and subsequent environmental cleanup.
Similar indexed content
Generic form or header page from the Department of Environmental Protection regarding general World Trade Center notices and requests.
Similar indexed content