NYC 9/11 Public Portal Document

Ahsan Z, Farooqi -6- November 12 2001

Proposed Phase 1 Testing Protocol

Ehc following sampling summary is proposed for air (Table 1), surfaces (Table 2), and molds and fungi (Table 3). The final parameter list and sampling and analytical techniques to be employed will be determined in concert with the BOE’s analytical laboratory. The proposed sampling program is summarized below;

0 Baseline Air Monitoring Program It is proposed to conduct baseline air sampling at four locations inside the school, two locations outside the school within the play areas, one location on the school roof, one location outside the school at the corner of Warren and Greenwich Streets, and one location between the school and Ground Zero, possibly in the area of Greenwich Street and Park Place or Barclay Street. In addition, ENVIRON proposes to collect one outdoor control sample and one indoor control sample at a location remote from the school and Ground Zero, potentially at the St. Bernards school, where the P.S. 234 students are Currently attending classes, or another appropriate location. The specific analyses are summarized in Table 1 and include VOCs, SVOCs, PCBs, dioxins and dibenzofurans, metal;: and cyanide, asbestos and particulates, and direct readings or other measuremenrs of carbon dioxide, carbon monoxide, hydrogen sulfide, chlorine gas, nitrous oxides .and sulfur dioxide. To develop the baseline conditions, it is proposed to conduct sampling on three separate days in order to assess potential variability in air quality. Ideally, the three sampling dates should cover varying weather conditions, including clear and overcast day.s and varying wind directions, and at least one .sampling event should be performed during generally southerly wind condirions. The results of these samples will be compared with the relevant PRGs and ERPG screening levels, as previously discussed, as well as available information on background levels.

O Baseline Surface Monitoring Program Given the limited nature of prior surface sampling in the school and the fact that virtually all of the surface samples were collected prior to the cleanup of the school, one additional round of surface sampling is proposed in order to evaluate the effectiveness of the previously completed scliool cleanup and the impact of potential dust settling in the month since rhe cleanup was completed. This surface sampling would focus on surfaces inside the school, concentrating on areas of highest likely exposure for children, including desks, banisters, the lunchroom, library, and gymnasium. This sampling would be performed if the results of the Baseline Air Monitoring Program discussed above indicate that it is reasonable to consider reopening the school in the near future. If the results of the Baseline Air Monitoring indicate that conditions do not appear acceptable to consider the reopening of the school in the near future, then the surface monitoring would be postponed until conditions improve sufficiently to consider reopening the school, The specific analyses are summarized in Table 2 and include PAHs, PCBs, dioxins .and dibenzofurans, metals, and asbestos. It is expected drat the Baseline Surface Monitoring would be performed once, with all samples collected during one day. The results of the Baseline Surface Monitoring sampling will be compared to available standards for surfaces, which have been established for certain parameters, such as PCB.s and lead. For ocher contaminants, ENVIRON may develop screening levels based on the approaches utilized for the PCB and/or lead stand,ards, depending upon their applicability to the conditions within a school.

® Evaluation of Molds and Fungi In order to assess whether the presence of water in the school basement during the period following September 11 when there was no electrical power at the school has resulted in the development of a mold or fungus issue within the school, it is proposed co collect random

CITY_21MC100_012173132

NYC-WTC_000276287

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000276287Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000106411 · Box DEP Box 37

Union memorandum regarding environmental monitoring and cleanup protocols following the closure of Stuyvesant High School after the September 11 attacks.

Similar indexed content

NYC-WTC_000149798 · Box DEP Box 10

Generic form or header page from the Department of Environmental Protection regarding general World Trade Center notices and requests.

Similar indexed content

Compare copies and versions →