H. A. Bader Consultants, Inc. Environmental Consulting Engineers 88 Bleecker Street, Suite 4E New York, New York 10012

□ward A. Bader, P.E. TEL; 212-475-412; esident FAX: 212-477-894

February 7, 2002

Stuyvesant High School Parents’ Association 345 Chambers Street New York, New York 10282-1099

Dear Parents:

This morning I received a report from ATC Associates for lead wipe surface testing at Stuyvesant High School. The testing was performed on February 6, 2002. The U.S. Federal Department of Housing and Urban Development (HUD) and the City of New York Department of Health (DOH) have established allowable levels of lead dust in settings occupied by children. The HUD/DOH clearance level is 40 micrograms per square foot (:g/ft2) for floor surfaces and 250 :g/ft2 for window sills.

On February 6, 2002, elevated lead concentrations were detected on floor surfaces in the 5"’ Floor Hall (312 :g/ft2) and in Classroom 635 (204.8 :g/ft2). Exposure to excessive levels of lead dust can cause brain, nervous system, and organ damage.

Lead testing was only performed in 3 classrooms and lead was detected in all 3 areas. The other classrooms were Rooms 701 and 838. These 3 classrooms are intended to be representative of all classrooms in the school (one per exposure, north, east and south). The lead concentrations detected in Classrooms 701 (floor 19.8, sill 53) and 838 (floor 19.9, sill 100.6 :g/ft2) were significant, however levels were less than the HUD/DOH clearance levels.

Based on the date of construction, it is believed that there is no internal source of lead in the building. The entire building (except the ventilation air distribution systems) were thoroughly cleaned prior to re-occupancy on October 9, 2001. Lead contamination attributed to World Trade Center collapse and cleanup has been identified outdoors in lower Manhattan.

While elevated lead concentrations on floor surfaces can often be attributed to tracking (i.e., dust on shoes) from outdoors, lead contamination on window sills is an indication that airborne lead contaminated dust is entering the building. The primary pathways for dust to enter the classrooms are the windows and the classroom HVAC unit ventilators. Since opening windows in the building is not allowed, the unit ventilators are the primary focus. Testing by the Board of

CITY_21MC100_012173057

NYC-WTC_000276212

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000276212Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000106411 · Box DEP Box 37

Union memorandum regarding environmental monitoring and cleanup protocols following the closure of Stuyvesant High School after the September 11 attacks.

Similar indexed content

NYC-WTC_000149798 · Box DEP Box 10

Generic form or header page from the Department of Environmental Protection regarding general World Trade Center notices and requests.

Similar indexed content

Compare copies and versions →