NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 39 pages

Testing Carpet: Asbestos Reservoir, EPA memo, 2002

Machine-extracted title · confidence 32%

EPA memorandum describing ultrasonication carpet dust test method for asbestos.

NYC-WTC_000275438–000275476
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Table 4. RE-CALCULATION OF REGION 1 DUST BENCHMARKS USING MORE VALID VALUES

FORMULA USED BY REGION 1;

Benchmark for X K-Factor (K-Factor Air Levei, structures per asbestos in Dust expressed as an milliliter (s/mL) (s/cm2) exponential)

45,000 X 0.000001 ( 10-6) 0.045

This IS the level derived from the This IS the K-factor chosen by Region 1 for their This IS the alleged background outdoor formula by Region 1 calculations, from the 2 highest ones from a total of six K- air level put into the formula by Region 1 factors A higher K-factor results in a calculation of a This value is the one highest higher, less protective dust level The two K-factors with measurement found in an early 1983 10(-6) values were for a person cleaning out a storage study For most of the measurements, room and for a person vacuum cleaning asbestos was not even detectable

1,000 X 0.00001 ( 10-=) 0 or Dust level if detection limit of the early This is the K-factor more applicable to a school. This is the detection limit of the study 1983 study is used, and K-factors representing gym activities and a person sweeping floors cited Most of the actual measure air more applicable to a school are used with a broom levels were below this detection limit

100 X 0 000001 (10-6) 0 0001 Dust level if air concentration is urban This is STILL the inappropnate K-factor chosen by Region Outside ambient air level, urban areas, level cited by the CDC's ATSDR, but 1 for their calculations found credible by the CDC's ATSDR still using the inappropriate K-factor

10 X 0 000001 ( 10-®) 0.00001

Dust level if air concentration is rural This is STILL the K-factor chosen by Region 1 for their Outside ambient air level, rural areas, level cited by the CDC's ATSDR, but calculations found credible by the CDC's ATSDR still using the inappropriate K-factor

10 X 0.00001 ( 10-®) 0.0001

Dust level if K-factors more relevant This is the K-factor more applicable to a school. Outside ambient air level, urban air, to school used, and ATSDR value for representing gym activities and a person sweeping floors found by the CDC's ATSDR urban outdoor air used with a broom

1 x 0 00001 { 10-®) 0.00001 Dust level if K-factors more relevant This is the K-factor more applicable to a school. Outside ambient air level, rural areas. to school used, and ATSDR value for representing gym activities and a person sweeping floors found by the CDC's ATSDR rural outdoor air used with a broom

1 X 0 0001 ( 10-*) 0.0001 Dust level if average of the six K- Average of six different K-factors in study, allowing Outside ambient air level, urban air, factors used, and ATSDR value for for a safety margin of error found by the CDC's ATSDR urban outdoor air used

0.1 X 0.0001 ( 10-*) 0.00001 Dust level if average of the six K- Average of six different K-factors in study, allowing Outside ambient air level, urban areas, factors used, and ATSDR value for for a safety margin of error found by the CDC's ATSDR rural outdoor air used

- 17-

CITY_21MC100_006815017

NYC-WTC_000275454

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000275454Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →