Table 3. ATSDR AIR LEVEL FINDINGS COMPARED TO LEVEL CHOSEN BY REGION 1

Background ambient air levels are from studies determined to be the most credible by the ATSDR®"*

Concentration in TEM Equivalent concentration in structures per milliliter PCM fibers per milliliter (s/mL) This includes all (PCM f/mL). PCM fibers asbestos fibers and are only those single fibers bundles of fibers, and so which are longer than 5 IS higher than "PCM” micrometers with a certain fibers. aspect ratio

expressed as expressed as exponential exponential

ATSDR finding: outside air, rural, no 0 00001 (1 X 10’=) 0.0000002 (2 X 10’^) known source of asbestos contamination nearby

ATSDR finding; outside air, urban, no 0.0001 (1 X 10-*) 0.000002 (2 X 10-®) know source of asbestos contamination nearby

ATSDR finding' 1988 EPA survey of 94 0 006 (6 X 10 ®) 0 0001 (1 X 10-^) public buildings containing asbestos materials, mean concentration

ATSDR finding. 1988 EPA survey of 41 0.03 (3x10-^) 0.005 (5 X 10-*) schools containing asbestos materials, mean concentration

AH ERA TEM clearance test level, the “70 0.02 (2 X 10'2) 0 01 (1 X 10'^) structures per square centimeter” level, approximately converted to s/mL and PCM equivalent f/mL This IS an unsafe level for long term exposures.®^

Region 1 level for background outside air, 0.045 (4.5 X 10'2) unknown used for risk assessment

Region 1 failed to use real-world background dust levels

There was no reason for Region 1 to have gone through any calculation process to project background dust levels from air levels. Typical background dust levels are well established, just like typical air levels.

Region 1 chose to ignore the fact that the same reference®® they used for K-factors also contained real world data for typical dust levels, which are widely recognized by industrial hygienists and other asbestos abatement specialists. See Table 2 for typical dust levels for buildings with or without asbestos contamination problems. Compare 200 s/cm\ a real world background level for buildings that do not contain asbestos materials, with Region I's calculated level of 45,000 sc nr.

- 15 -

CITY_21MC100_006815015

NYC-WTC_000275452

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000275452Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →