EPA/health risk comparison, WTC draft, 2002

Machine-extracted title · confidence 34%

12-page draft comparing detection limits and health-risk thresholds for WTC-related toxics.

NYC-WTC_000275341–000275353
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

AIR, INTERIOR AND EXTERIOR

For inside air, all hazardous substances which may be associated with particulates (asbestos, fine particulates, fiberglass, metals, dioxins and furans, PCB’s) must be tested using EPA’s aggressive inside air testing protocols, which simulate human activities which disturb dusts. This testing protocol is paramount to simulating the actual breathing zone of a small children who may jump on a couch or roll or run around a carpet. This testing may be found in EPA’s regulation for conducting the asbestos clearance test at Title 40 of the Code of Federal Regulations, Part 763, Appendix A, Unit III.B.7. This testing requires the use of a one-horsepower minimum leaf blower directed at all surfaces followed by fans to keep particulates suspended.

This type of aggressive air testing should not be carried out in current^ occupied spaces, as it could serve to re-distribute contamination as well as displace small objects. However, there are many vacant apartments containing contaminated carpeting in Lower Manhattan, and plenty of contaminated upholstered furniture which could be placed in these apartments for aggressive air testing. EPA should gain access to conduct the necessary testing. For outside air, monitors should be placed close to the ground to simulate the breathing zone of a small child.

AIR, INTERIOR AND EXTERIOR HEALTH-BASED STANDARDS EPA’s WTC TESTING DETECTION LIMITS AND/OR REQUIRED DETECTION LIMITS OTHER TEST METHOD DETECTION LIMITS

UNITS FOR ASBESTOS AND FIBERGLASS IN AR UNITS FOR OTHER AIR SUBSTANCES S/mL = structures per milliliter = s/cc = structures per cubic centimeter pg/m3 = picogram per ciblc meter; ng/m3 = nanogram per cubic meter, structures = asbestos fibers plus bundles of fibers ug/m3 = micrograms/m3; mg/m3 = millig-ams/m3 1 ug = 1000 ng, 1 mg = 1000 ug s/mm^ = structures per square millimeter, a given area of filter through which air is drawn There is no direct way to convert s/ccto s/mn? without knowing the volume of air sampled. ppm = part per million; ppb = part per bllion; ppt = part per trillion, ppq = part per quadrillion 1 ppt = 1000 ppq, 1 ppb = 1000 ppt, 1 ppm = 1000 ppb

ASBESTOS (air) 0.000004 sAmL Based on health risk level. 0.000004 f*nL 10' cancer risk level, from detection Irnit: EPA’s detection limit for for the PLM faction, also with EPA’s Integrated Risk outside air, outside air, WTC all structures quantified Inside buildings, test under Information System (IRIS) < 0.0048 s/m3 evaluation aggressive conditions, using = < 8.89 s/mnf EPA’s regulations at 40 CFR § 763 App.A, Unit III.B.7

detection Irnit: The AHERA “clearance test" level, which is not a standard, but instead a method 0.02 s/mL detection limit. This test misused by EPA o = 70 s/mirf and NYC DOH since samples taken under passive condtions and in lieu of abatement. Level is also grossly unprotective even if to samples were taken under aggressive S conditions. O o o I o

o -2- co cn

NYC-WTC_000275342

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000275342Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000348699

COPC committee report with contributors from EPA, NYC DEP, and state agencies.

Similar indexed content

NYC-WTC_000348649

COPC committee report on World Trade Center contaminants with multi-agency authors.

Similar indexed content

Compare copies and versions →