STUYVESANT HIGH SCHOOL LEAD4N-WIPE-DL/ST MERCURY PCB’S SILICA (RESPIRABLE , FIBERGLASS HYDROCARBONS DIOXINS WIPE SAMPLE METALS SAMPLE DUST) Date ^of Lead Lead Mercury Concentration Range of Range of Results . Indoor Outdoor Indoor Air Plenum Indoor Outdoor Sample Cone. On Cone. On Cone. (3 samples per Indoor Cone. Outdoor Cone. (10 samples Readings Reading Surfaces Cone. Readings Reading Floor Window (mg/m^) <iay) (11 samples (1 sample day) per day) ' (2 samples (1 sample Range of Cone. (1 sample (2 samples (] sample (fg/ft-) Sill (Mg/cm2) per day) per day) per da)') (2 samples per per day) per day) per day) (pg/rf) day) (ng/m’) (mg/m^) (mg/mb (no/m*) 01/23/02 17 Below Guidance Level .Mercury was not Below reporting No silica was found above detection limit. Non Detected None detected None detected 3 wipe samples (-^-1 blank) were The levels of airborne metals did (+ 2 blks) detected in any of limit of2 pa/ above limits above limits collected for dioxin. The levels found in not exceed the limits of detection the samples at a sample of detection of detection these samples are below the NYSDOH in any of the samples except for level greater than guideline of25 ngi'm’. chromium which was also found in the blank in the blank. 01/29/02 I Non Detected 01/30/02 17 Below Guidance Level 3 air samples were 3 wipe samples for 12 air samples (+ 1 blank) for silica were Chloroform Non Detected 3 wipe samples (+1 blank) were • 3 air samples for metals were- (+• 2 biks) collected for PCBs were collected. Silica was not detected on any was delected collected for dioxin. The levels found collected. The levels of airborne mercuiy- Mercury collected. The PCB of the samples collected. in both indoor in these samples are below the metals did not exceed the limits was found in all results of all samples (Main NY5DOH guidelines of25 ng/m^ of detection in any of the samples three samples at a samples were below lobby = 0.049 except for chromium which was very low levels. the reporting limits ppm and 2“* also found in the blank. of 2.0 ug/sample. floor bridge entrance = 0.14ppn)). 02/06/02 17 5** Floor Below 3 air samples were 3 wipe samples for 12 air samples (+ 1 blank) were collected Nop Detected 3 air sample were collected for 3 wipe samples (+1 blank) were 3 air samples for metals were (+ 2 blks) Hallway and Guidance collected for PCBs were for silica. Silica was detected in only one HC, NO hydrocarbons were collected for dioxin. Dioxins were not collected. The levels of airborne Room 635 Level mercury vapor. collected. The PCB sample collected in the pool area. It detected in the analytical panel detected in two sampes including blank. metals did not exceed the limits floor fXJterthe samples results of all contained 0.0135 mg/m’ of silica. ' were present above the limits of The level found in the HVAC #1 of detection in any of the samples surfaces are arc blank samples were below detection in any of the samples. Simple was below die NYSDOH except for chromium and above the corrected, the the reporting limits guideline of25 ng/m* aluminum which was also found guidance max. of 2,0 ug/sample. tn the blank. limit of 40 concentrations in the indoor and outdoor samples fall below the limit of detection. 01'07/02 6 Below Guii a/ice Level O (follow up samples) (+I H blank)

NJ

S O o o I

o Stuy-104 NJ O

NYC-WTC_000274928

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000274928Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000428888

Summary of wipe and air sampling results at Stuyvesant High School, provided for NYC Board of Education.

Similar indexed content

NYC-WTC_000428697

Summary of wipe and air sampling at Stuyvesant High School per ATC 15-19125-0246.

Similar indexed content

NYC-WTC_000425450

Summary of wipe and air sampling results for Stuyvesant High School; includes tables of results.

Similar indexed content

NYC-WTC_000444431

Summary of wipe and air sampling results at Stuyvesant High School, March 2002.

Similar indexed content

Compare copies and versions →