Soil and work data analysis, 1993

Machine-extracted title · confidence 62%

Data analysis of soil work under EPA contract, Sept 1993.

NYC-WTC_000274857–000274871
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Paint surface areas, dwelling unit age, number of occupants, and the number of rooms are almost <' never significant.

The relative magnitude of the soil and paint parameters suggests that soil sources contribute more lead to the floor dust than do paint sources. However, the paint lead term in the model for predicting dust lead in dry rooms is larger and more significant than in models to predict dust lead concentrations in wet rooms or at dwelling entrances.

For the samples from wet room floors, the dust lead concentrations for samples collected on rugs were significantly lower than for samples collected on bare floors. In addition, the dust lead concentrations for samples collected in rooms on the second or higher floors were significantly lower than for samples collected in first floor rooms. Similar relationships were not found for samples collected in the dry room and dwelling unit entrance.

Overall, the regressions explained only 25 percent or less of the variance in the lead concentration measurements from floor samples, indicating that th.e regression equations have little predictive power. There are likely to be other factors that explain the variation in the dust concentrations that were not measured as part of the survey. Although the overall regression models provided a highly significant fit to the floor dust concentration data, caution is recommended when interpreting the results.

To summarize the results for the regressions on floor dust:

The parameter estimates are consistent with the conclusion that soil contributes more lead to floor dust than does paint lead.

Paint damage is associated with a significant increase in the interior (wet and dry room) dust lead concentrations and in the entrance dust lead concentrations in the presence of high exterior paint lead concentrations.

The parameter estimates are consistent with the conclusion that lead in dust at the entrance to the dwelling unit comes almost exclusively from exterior soil sources.

6.3.2 Window Sill Dust Lead?

A review of Tables 6-14 and 6-15 indicates different patterns in the parameters for the wet and dry rooms. Paint lead from the wet room is a significant predictor of both dry and wet rooms window sill lead concentrations. However, this conclusion for the dry room window sills should be interpreted with caution because the signs of the parameters for paint damage and painted surface area are negative, which is opposite of what would be expected if paint lead provides a significant contribution to the window sill dust concentrations. Although the dry room data indicates a very significant link between the soil close to the dwelling unit and the dry room window sill dust concentrations, the regression results suggest that soil provides no lead to the wet room window sill lead. As with the floor samples from the wet room, window sill lead concentrations for samples from the wet room are lower when collected in rooms on the second or higher floors than from rooms on the first floor. A window sill, as discussed in Section 1.2 of this report, is the lower interior ledge of a window.

97

NYC-WTC_000274870

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000274870Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000320385

Oldraft report for World Trade Center background study prepared for FEMA, EPA Region 2.

Similar indexed content

Compare copies and versions →