NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 15 pages

Soil and work data analysis, 1993

Machine-extracted title · confidence 62%

Data analysis of soil work under EPA contract, Sept 1993.

NYC-WTC_000274857–000274871
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Soil lead analyses are reported here for privately-owned, occupied housing built before 1980. Post- 1980 and vacant housing were outside the scope of the National Survey. While public housing was included in the National Survey of Lead-Based Paint in Housing, the public housing soil and dust data are somewhat suspect, as discussed in the Report On The National Survey Of Lead-Based Paint In Housing. Specifically, vacant public housing units were over-represented in the sample, and dust lead levels and incidence of damaged paint were lower in, public housing than in private housing. In addition, many public housing units had all the property paved; there was no soil on the premises. Public housing data has therefore been excluded from this study. There were no similar problems associated with the data from private dwelling units.

Prior analyses of soil lead data from the National Survey of Lead-Based Paint in Housing appear in three reports: (1) the Comprehensive and Workable Plan for the Abatement of Lead-Based Paint in Privately Owned Housing: Report to Congress, prepiired by HUD; (2) the Report On The National Survey OfLead-Based Paint In Housing, prepared for EPA and composed of three volumes; and (3) the Analysis of Soil and Dust Samples for Lead (Pb), also prepai ed for EPA.

These prior analyses indicate that an estimated 18 percent of privately-owned housing units have soil lead levels in excess of 500 ppm (although tliere is no federal standard for residential soil lead contamination, many experts agree that 500 ppm is a feasible threshold to designate "high" soil lead contamination in residential environments). EPA’s interim guidance on soil lead cleanup levels at Superfund sites sets the cleanup levels at 500 to 1000 ppm'. The prior analysis also indicates that a similar 18 percent of homes have dust lead loading levels in excess of the HUD federal action levels as reported in the HUD Interim Guidelines for hazard identification and abatement of lead-based paint in housingC-200 pg/sq ft on floors, 500 pg/sq ft on window sills, and 800 pg/sq ft on window wells. (One important caveat, however, should be noted when comparing dust loadings measured in the National Survey to the HUD guidelines. In the national survey, dust was collected with a vacuum sampler, while the HUD guidelines are based on dust wiped from surfaces with wet wipes. Relationships between different dust collection techniques are not fully studied). The analyses also found a statistical association between the presence of damaged lead-based paint ("lead-based paint" is defined by HUD as containing a paint leadconccntration of l.Omg/sqcmorgrcatcr) and elevated soil and dust lead levels. This is a significant finding in light of potential exposures to children.

1.2 National Survey Methodology

This section presents a brief description of the objectives and methodology of the national survey of lead-based paint in housing. The objective of the national survey was to obtain data for estimating: (1) the number of housing units with lead-based paint; (2) the surface area of lead-based paint in housing and the associated estimate of national abatement costs; (3) the condition of the paint; (4) the incidence of lead in dust in housing units and of lead in soil near residential structures; and (5) the characteristics of housing with varying levels of potential hazard to examine possible priorities for abatement.

The study population consisted of nearly all housing in the United States constructed before 1980. Newer houses were presumed to be lead-free because, in 1978, the Consumer Product Safety Commission

'u.S. Environmental Protection Agency (September 7,1989), Interim Guidance on Establishing Soil Lead Cleanup Levels at Superfund Sites (OSWER Directive # 9355.4-02).

^U.S. Department of Housing and Urban Development (1990), "Lead Based Paint: Interim Guidelines for Hazard Identification and Abatement in Public Housing", federal Register 55 (April 18): 14557-14789.

2

NYC-WTC_000274866

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000274866Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000320385

Oldraft report for World Trade Center background study prepared for FEMA, EPA Region 2.

Similar indexed content

Compare copies and versions →