Altliough the lead-in-dust samples collected at Stuyvesant HS (M477) were not collected in response to lead abatement, the same thresholds are used since no other regulations or standards are applicable to this project.

Sampling Methodology ATC provided all laboratory analytical services in support of this limited inspection. ATC is certified by the New York State Department of Health’s Environmental Laboratory Accreditation Program to perform lead and related analyses of environmental samples (Laboratory ID Number; 10879). The laboratory utilizes the United States Environmental Protection Agency analysis method number SW846-7420 and the National Institute of Occupational Safety and Health method number 7082M.

The lead-in-dust samples were obtained by gently wiping a pre-measured surface area with non-alcohol moistened towelettes. ATC’s representative wore disposable gloves; a new glove was worn with each new sampling procedure, and care was taken to avoid contamination of the towelette and collection vial. Towelettes were then placed into 50ml plastic vials and immediately sealed. The chain of custody form was completed and documents the measurement of the area sam pled.

Results of Dust Wipe Sampling Seventeen (1 7) dust wipe samples were collected from areas indicated to ATC. Laboratory analysis is shown that the dust wipe samples collected from the 5"' floor cafeteria and the 1“ floor lobby floor surfaces and the 3“' floor Auxiliary gymnasium window sill surface contain lead in dust above the guideline level of 40 pg/ft’ and 250 pg/fV respectively. See laboratory report and chain of custody for more details.

Recommendations Based on the lead dust wipes laboratory results, ATC recommends the following: • Thoroughly clean the 5"’ floor cafeteria and L' Poor lobby floor surfaces and the 3'‘'floor auxiliary gymnasium window sill surfaces; • Collect additional dust wipe samples from the aforementioned locations after the cleaning is completed.

Limits of the limited dust wipe sampling Dust sampling was conducted at the NYC-BOE request. The results of this report are applicable for the time the testing was performed. If questions arise concerning lead content in or on components not tested by ATC, then additional testing services should be procured. ATC makes no representation or warranty concerning the standards and specifications provided in the HUD Guidelines and the NYC-BOE protocol. c CD E 3 o o Q o TO co ■c o Q_ CM o O O Z Sdiyvesci/it /LS O 3 I 0. Jaiinti/y 3. 2(f02 o

O 6 z CITY_21MC100_009017771

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000274830Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →