NYC-WTC_000400125
ATC indoor air quality measurements report for PS 89M, Warren Street, March 1, 2002.
13 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗ATC IAQ evaluation report for P.S. 89M; Mar 4, 2002.
NYC-WTC_000274686–000274689OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Mr. Bernard P. Orlan March 4, 2002 Indoor Air Quality Assessment Page 3 P. S. 89M ATC Proiect No. 15-19125-0297
Real-Time Environmental Measurements
ATC collected eighty (80) sets of real-time environmental measurements consisting of seventy (70) from inside the school building and ten (10) from outdoors. All five floors of the school building were surveyed. These results are described below.
Field data sheets are found in Attachment 1. Readings began at 8:00 A.M. and concluded at approximately 12:00 P.M.
Temperature
Indoor dry bulb temperature measurements ranged from 67.6 °F to 74.4 °F. One (1) of the indoor measurements were below the range of 68 to 75°F (at 50 percent relative humidity) as recommended by the ASHRAF Standard 55-1992 during the heating season (wintertime conditions). The outdoor temperature measurements ranged from 36 to 40.8 °F.
Relative Humidity
The relative humidity indoors ranged from 12.3 to 18.4 percent. All of the measurements were below the ASHRAE-recommended range of 30 to 60 percent for occupant comfort. The outdoor relative humidity measurements ranged from 13.3 to 17.1 percent.
Carbon Dioxide Concentration
Carbon dioxide concentrations indoors ranged from 553 ppm to 1291 ppm. One (1) of the CO? measurements was above the ASHRAF Standard 62-1999 recommended maximum concentration of <700 ppm above the background level. The maximum outdoor (background) CO2 concentration was 490 ppm. Therefore, the maximum acceptable level of COg at this location was 1190 ppm (background level + 700 ppm). The highest COg measurement was collected from room 506 at 9:00 AM with 26 occupants. Levels above the recommended maximum do not indicate a health risk. Carbon dioxide measurements are used as an indicator of available outside makeup air. The primary source of COg indoors is occupant respiration. The school building was occupied during ATC’s assessment.
Carbon Monoxide Concentration
Carbon monoxide concentrations indoors were 0 ppm for all readings.. These concentrations were below the NPAAQS/ASHRAE guideline of 9 pprn. The outdoor CO concentration was also 0 ppm for all collected readings.
Respirable Particulates (PM2,5)
Respirable particulate concentrations* indoors ranged between 7 pg/m^ to 27 pg m-. None of the measurements were above the NPAAQS of 65 pg/m^ 24-hour average concennation of particulate matter 2.5 micrometers or less in aerodynamic diameter. The average PM2.5 concentration for the entire school building was approximately 19 pg/m^. The PM2.5 average concentration was below the USEPA recommended concentration of 40 pg/m^ for sensitive
CITY_21MC100_003109883
NYC-WTC_000274688
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000400125
ATC indoor air quality measurements report for PS 89M, Warren Street, March 1, 2002.
13 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000400288
BOE IAQ measurements at PS 89M; March 22, 2002.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000313420
IAQ measurements at PS 89M; BOE evaluation requested, March 26, 2002.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000400303
IAQ measurements at PS 89M for BOE; March 25, 2002.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000400315
IAQ measurements collected March 26, 2002 for BOE.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000313424
IAQ measurements at PS 89M; BOE requested evaluation, March 27, 2002.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000383913
ATC IAQ report for P.S. 89M building requested by BOE.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000400182
IAQ field report for PS 89M, March 11, 2002, ATC.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000383816
Indoor air quality measurements collected March 11, 2002 at PS89M for BOE evaluation.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000226849
Cover letter from ATC Associates to the Board of Education submitting indoor air quality measurement results for PS89M.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000383939
ATC report of IAQ measurements collected for BOE evaluation.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000383927
ATC report of indoor air measurements at PS 89M for BOE evaluation.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000326715
ATC indoor air quality measurements at PS 89M, March 1, 2002, for NYC BOE.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000313420
IAQ measurements at PS 89M; BOE evaluation requested, March 26, 2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000400125
ATC indoor air quality measurements report for PS 89M, Warren Street, March 1, 2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000400303
IAQ measurements at PS 89M for BOE; March 25, 2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000400315
IAQ measurements collected March 26, 2002 for BOE.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000313374
March 19, 2002 IAQ report for PS 89M site measurements.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000400125
ATC indoor air quality measurements report for PS 89M, Warren Street, March 1, 2002.
Similar indexed content
NYC-WTC_000400288
BOE IAQ measurements at PS 89M; March 22, 2002.
Similar indexed content
NYC-WTC_000313420
IAQ measurements at PS 89M; BOE evaluation requested, March 26, 2002.
Similar indexed content
NYC-WTC_000400303
IAQ measurements at PS 89M for BOE; March 25, 2002.
Similar indexed content
NYC-WTC_000400315
IAQ measurements collected March 26, 2002 for BOE.
Similar indexed content