NYC-WTC_000271375
TEM air sample analysis results for Stuyvesant High School, AHERA method, 11/9/01.
8 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗TEM results with asbestos concentration metrics for sampled areas.
NYC-WTC_000273608–000273610OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Attn; Mr. Bernard Orlan Received; 11/8/01 9:00:00 PM N.Y.C. Board of Education 28-11 Queens Plaza North ATC Group#: 5860
Long Island City, NY 11101 Analysis Date: 11 /9/01 Fax; (212) 475-4122 Phone; (212)477-8941 Project; New Stuyvesant H. S. , 345 Chambers St., NY , NY Exterior and Interior of Building and Roof
Asbestos Fiber Analysis by Transmission Electron Microscopy (TEM) Performed by EPA 40 CFR Part 763 Final Rule (AHERA) Analytical Asbestos Area Non >isbestos Structures Sensitivity Concentration Sample Colume Analyzed Asb 0.5^-5 5fi (S/cc) (S/mm‘) (S/cc) Notes 9 1944.00 0.0450 0 None Delected 0 0 0.0044 <22.24 <0.0044 5860 -9
’0 - 1944.00 0.0450 0 None Delected 0 0 0.0044 <22.24 <0.0044 5860 -10
11 1920.00 0.0450 0 None Detected 0 0 0.0045 <22.24 <0.0045 5860 -11
12 - 1928.00 0.0450 0 AMOSITE 0 1 0.0044 22.24 0.0044 5860 -12
13 - 1928.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044 5860 -13
14 1936.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044 5860 -14
15 - 1928.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044 5860 -15
16 - 1928.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044 5860 -16
- 1928.00 0.0450 0 None Detected 0 0 0.0044 <22.24 < 0.0044 5860 -17
- 1936.00 0.0450 0 None Delected 0 0 0.0044 <22.24 <0.0044 5860 -18
ROMAN PEYSAKHOV MICHAEL A. GORYCKl, Ph.D.
Analyzed by: Approved by:
Disclaimer: The laboratory is not responsible for data reported in structures/cc, which is dependent on volume collected by non-laboratory personnel. This lab is only responsible for data reported in stnjctures/mmT This report may not be reproduced, except in full, without written approval by ATC Associates Inc. This report may not be used to claim product endorsement by NVLAP or any other agency of the U.S. Government. This reports relates only to the samples reported above. Quality control data (including 95% confidence limits and laboratory and analysis' accuracy and precision) is available upon request.
Accredited for NVLAP PLM/TEM #101187-0, NY State ELAP #10879
CITY_21MC100_0 03106235 NYC-WTC_000273609
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000271375
TEM air sample analysis results for Stuyvesant High School, AHERA method, 11/9/01.
8 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000379743
TEM analysis of air samples at New Stuyvesant High School, Feb 2002.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000273589
AHERA TEM results detailing asbestos concentrations from building samples.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000398932
TEM analysis data for asbestos content in samples from New Stuyvesant High School.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000380676
TEM asbestos analysis results for exterior/interior of New Stuyvesant High School building.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000294168
TEM asbestos analysis of exterior/interior air samples at New Stuyvesant High School, Nov 2001.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000398852
Lab TEM asbestos analysis results with sample details for DOE project.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000379315
TEM asbestos analysis results for 6293, New Stuyvesant HS, Jan 2002.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000398754
AHERA TEM asbestos analysis of exterior/interior building samples for New Stuyvesant High School, Dec 2001.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000378801
Fiber analysis TEM data with sample IDs and counts for New Stuyvesant High School.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000294286
TEM analysis results for air samples at New Stuyvesant High School exterior/interior.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000294216
TEM microscopy results; exterior/interior building samples.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000299262
TEM asbestos analysis results for New Stuyvesant High School building interior/exterior samples.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000273707
AHERA TEM asbestos analysis of exterior/interior building samples for NYC DOE, Nov 2001.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000273655
TEM analysis report for asbestos at New Stuyvesant High School, clearance context.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000300153
TEM asbestos analysis results for exterior and interior building areas under AHERA.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000191016
Laboratory report from ATC Associates detailing transmission electron microscopy analysis of air samples for asbestos at a New York City Board of Education school.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000378359
Chain-of-custody for TEM asbestos samples from New Stuyvesant H.S., Dec 4, 2001.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
TEM air sample analysis results for Stuyvesant High School, AHERA method, 11/9/01.
Similar indexed content
NYC-WTC_000379743
TEM analysis of air samples at New Stuyvesant High School, Feb 2002.
Similar indexed content
AHERA TEM results detailing asbestos concentrations from building samples.
Similar indexed content
TEM analysis data for asbestos content in samples from New Stuyvesant High School.
Similar indexed content
TEM asbestos analysis results for exterior/interior of New Stuyvesant High School building.
Similar indexed content