NYC-WTC_000298708
Asbestos fiber TEM results for air samples at the school, AHERA methodology.
7 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗TEM asbestos analysis report for building samples at New Stuyvesant High School.
NYC-WTC_000273363–000273365OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Attn: Mr. Bernard Orlan Received: 6/7/02 7:30:00 PM N.Y.C. Board of Education ATC Group#: 7998 28-11 Queens Plaza North Analysis Date: 6/8/02 Long Island City, NY 11101 Fax: (212)475-4122 Phone: (212)477-8941 Project: New Stuyvesant H. S., 345 Chambers St., NY , NY
Asbestos Fiber Analysis by Transmission Electron Microscopy (TEM) Performed by EPA 40 CFR Part 763 Final Rule (AHERA) Analytical Asbestos /Irea Non Asbestos # Structures Sensitivity Concentration Sample t^olume Analyzed Asb Type(s) O.Sft-S 5/1 (S/cc) (S/mm^) (S/cc) Notes
8 1928.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044 7998 -8
9 1928.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044 7998 -9
10 1944.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044 7998 -10
11 1920.00 0.0450 0 None Detected 0 0 0.0045 <22.24 <0.0045 7998 -II
12 1920.00 0.0450 0 None Detected 0 0 0.0045 <22.24 <0.0045 799S -12
13 1920.00 0.0450 0 None Detected 0 0 0.0045 <22.24 <0.0045 7998 -13
14 1920.00 0.0450 0 None Detected 0 0 0.0045 <22.24 <0.0045 799S -14
15 1920.00 0.0450 0 None Detected 0 0 0.0045 < 22.24 <0.0045 7998 -15
16 1944.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044 7998 -16
MARK PEYSAKHOV MICHAEL A. GORYCKl, Ph.D.
Analyzed by: >proved ^y:
. . . - I Disclaimer. The laboratory is not responsible for data reported in structures/cc, which is dependent on volume collected by non-laboratory personnel. This lab is only responsible for data reported in structures/mmT This report may not be reproduced, except in full, without written approval by ATC Associates Inc. This report may not be used to claim product endorsement by NVLAP or any other agency of the U.S. Government This reports relates only to the samples reported above. Quality control data (including 95% confidence limits and laboratory and analysis’ accuracy and precision) is available upon request
Accredited for NVLAP PLWTEM #101187-0, NY State ELAP #10879
Page 2 of 3
CITY_21MC100_003105445
NYC-WTC_000273364
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000298708
Asbestos fiber TEM results for air samples at the school, AHERA methodology.
7 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000300246
TEM asbestos analysis results; AHERA method used for Stuyvesant HS samples.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000184613
Formal analytical report detailing TEM asbestos fiber counts for a specific high school project conducted by ATC Associates in June 2002.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000300139
Asbestos TEM results for air samples at New Stuyvesant High School exterior/interior.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000300220
TEM asbestos analysis report for New Stuyvesant High School exterior/interior areas.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000299957
TEM asbestos fiber analysis results for exterior/interior of New Stuyvesant High School, Apr 2002.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000191254
Request form for TEM asbestos analysis at a high school submitted by ATC Associates on May 18, 2002.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000298696
Asbestos fiber TEM analysis results for New Stuyvesant High School air samples, AHERA methodology.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000299929
TEM asbestos analysis results for exterior/interior areas, 04/08/02.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000185047
Formal laboratory report detailing transmission electron microscopy results for asbestos fiber analysis conducted on behalf of the New York City Board of Education.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000299119
Chain of custody and air monitoring data for TEM analyses at building site.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000191141
Formal laboratory report from ATC Associates detailing transmission electron microscopy results for asbestos fiber analysis at a New York City Board of Education school on May 12…
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000193544
Formal laboratory report from ATC Associates detailing transmission electron microscopy results for asbestos fiber analysis at a New York City Board of Education project dated…
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000299072
Asbestos fiber TEM analysis results for New Stuyvesant High School exterior/interior areas.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000298281
Asbestos TEM analysis performed on air samples per AHERA, building locations noted.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000298708
Asbestos fiber TEM results for air samples at the school, AHERA methodology.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000262704
TEM results for air samples from New Stuyvesant H.S. exterior/interior.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000298832
Asbestos TEM analysis results for New Stuyvesant High School project; AHERA test data and fiber concentrations.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
Asbestos fiber TEM results for air samples at the school, AHERA methodology.
Similar indexed content
TEM asbestos analysis results; AHERA method used for Stuyvesant HS samples.
Similar indexed content
NYC-WTC_000184613
Formal analytical report detailing TEM asbestos fiber counts for a specific high school project conducted by ATC Associates in June 2002.
Similar indexed content
Asbestos TEM results for air samples at New Stuyvesant High School exterior/interior.
Similar indexed content
TEM asbestos analysis report for New Stuyvesant High School exterior/interior areas.
Similar indexed content