ATC Environmental, Inc. 104 East 25th Street New York, New York 10010 N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/29/01 ASBESTOS FIBER ANALYSIS BY TR7kN5MI5SION ELECTRON MICROSCOPY (TEM) with Piber Identification by Selected-Area Electron Diffraction ISAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method: AHERA Final Rule, EPA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987
Sample Identification Analysis Parameters
Project/Site: New Stuyvesant H.S., 345 Chambers St., NY, NY TEM Sample No.: 5785 - 62421 Exterior & Interior of Building & Roof Date Received; 10/28/^- Grid Openings Analyzed;__ 4
Project Sample No. Average Grid Opening: 106.00 ym
Air Volume: 1920 liters Total Area Analyzed: 0.0450 mm2
Filter Typ e; MCE 25 mm diam. , Pore Size-. 0.45 urn Analytical Sensitivity; 22.2 s/mm2 Effective Area: 385 mm2 0.0045 s/cc
FIBROUS PARTICULATES ANALYZED Number Obseirved CONCENTRATION Total Single ’ Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct. Struct > = 5um Struct/mm2 Struct/cc nqm/m3
Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Amphibole Asbestos 0 0 0 0 0 0 0,0 0.0000 0
Ambiguous 0 0 0 •0 0 0 0.0 0 . 0000 0
Total asbestos (includes ambiguous structures) 0 0 • 0.0 0.0000 0 Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/A No Identification -0 0 0 ■ 0 0 0 0.0 0.0000 N/A
Totals (All Structures) 0 0 0.0 0.0000 N/A The estimated uncertainty of this analysis is 1 standard deviation.
Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected
The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.
Analyzed by: Report Reviewed by:
Marek Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy
CITY_21MC1OO_OO3O9994O
NYC-WTC_000270971
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000270861
TEM asbestos analysis for New Stuyvesant High School site, Oct 2001.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270665
TEM analysis by SAED/EDS for New Stuyvesant HS, exterior/interior, 10/2001.
8 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000292758
Asbestos fiber analysis by TEM for New Stuyvesant High School interior/exterior samples, report dated 10/29/01.
8 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293978
TEM analysis on exterior/interior building samples; TEM sample 5775, received 10/26/01, analyzed date similar.
8 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270717
Asbestos fiber analysis by TEM for New Stuyvesant High School, received 10/22/01.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270966
TEM asbestos analysis with SAED/EDS for New Stuyvesant HS exterior/interior, Oct 2001.
8 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293814
Asbestos TEM analysis with SAED/EDS for New Stuyvesant H.S., Oct 2001.
8 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293863
TEM asbestos analysis with diffraction and X-ray spectroscopy; received 10/23/01, analyzed 4.
8 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270668
TEM analysis of asbestos fibers at New Stuyvesant HS with SAED/EDS, Oct 2001.
8 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270549
TEM asbestos analysis for New Stuyvesant H.S.; SAED/EDS methods; includes date.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000188482
Laboratory report detailing asbestos fiber analysis by TEM and EDS for exterior and interior building samples.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293809
Asbestos TEM analysis with SAED/EDS for New Stuyvesant H.S., Oct 2001.
8 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000270861
TEM asbestos analysis for New Stuyvesant High School site, Oct 2001.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270665
TEM analysis by SAED/EDS for New Stuyvesant HS, exterior/interior, 10/2001.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000292758
Asbestos fiber analysis by TEM for New Stuyvesant High School interior/exterior samples, report dated 10/29/01.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293978
TEM analysis on exterior/interior building samples; TEM sample 5775, received 10/26/01, analyzed date similar.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270717
Asbestos fiber analysis by TEM for New Stuyvesant High School, received 10/22/01.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270966
TEM asbestos analysis with SAED/EDS for New Stuyvesant HS exterior/interior, Oct 2001.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000270861
TEM asbestos analysis for New Stuyvesant High School site, Oct 2001.
Similar indexed content
TEM analysis by SAED/EDS for New Stuyvesant HS, exterior/interior, 10/2001.
Similar indexed content
Asbestos fiber analysis by TEM for New Stuyvesant High School interior/exterior samples, report dated 10/29/01.
Similar indexed content
TEM analysis on exterior/interior building samples; TEM sample 5775, received 10/26/01, analyzed date similar.
Similar indexed content
Asbestos fiber analysis by TEM for New Stuyvesant High School, received 10/22/01.
Similar indexed content