NYC-WTC_000270384
TEM asbestos analysis report for exterior/interior of building, Oct 2001.
8 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗TEM asbestos analysis with SAED/EDS for New Stuyvesant HS exterior/interior, Oct 2001.
NYC-WTC_000270963OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
ATC Environmental, Inc. 104 East 25th Street New York-, New York 10010
N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long.Island City, NY 11101 Report Date: 10/29/01 •
ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method: AHERA 'Final Rule, EPA Federal Register (40 CPR, Part 763), Vol. 52, No. 210, October 30, 1987
Sample Identification Analysis Parameters
Project/Site: New Stuyvesant H.S., 345 Chambers St., NY, NY TEM Sample No.: 5785 - 62413 Exterior & Interior of Building & Roof Date Received: 10/28/^ Grid Openings Analyzed; 4
Project Sample No.: 4 Average Grid Opening; 106.00 um
Air Volume: 1928 liters Total Area Analyzed: 0.0450 mm2
Filter Type-. MCE 25 mm'diam.. Pore Size-. 0.45 um Analytical Sensitivity :22;2 s/mm2 Effective Area: 385 mm2 0.0044 s/cc
FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. struct. Filter Air Fibers Bundles Clusters Struct. Struct >=^Sum Struct/mm2 Struct/cc ngm/m3
Chrysotile Asbestos 0 0 C 0 0 0 0.0 0.0000 0
Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Ambiguous 0 0 0 0 0 0 0.0 0.0000 0
Total asbestos (includes ambiguous structures) 0 0 0.0 0.0000 0 Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/A - No Identification 0 0 0 0 0 0 0.0 0.0000 N/A
Totals (All Structures) 0 0 0.0 0.0000 N/A The estimated uncertainty of this analysis is 1 standard deviation.
No-n-asbestos fiber i.d. (EDS/SAED) : None detected •Amphibole Asbestos Type: None detected
The Analysis was carried out in accordance with the approved’ TEM method. This laboratory is in compliance with the quality specified for the method.
Analyzed by. Report Reviewed by:
Marek Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy
CITY_21MC100_0 03099932
NYC-WTC_000270963
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000270384
TEM asbestos analysis report for exterior/interior of building, Oct 2001.
8 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270967
TEM asbestos analysis with SAED/EDS for New Stuyvesant HS exterior/interior, Oct 2001.
6 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270853
TEM asbestos analysis for New Stuyvesant High School, Oct 2001.
8 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270551
TEM asbestos analysis for exterior & interior of New Stuyvesant H.S.; includes sample numbers and date.
8 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270810
TEM asbestos analysis, New Stuyvesant High School exterior/interior, received 10/24/01.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293940
TEM analysis of air samples at New Stuyvesant HS, exterior/interior, Oct 2001.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270258
TEM analysis of exterior facade at New Stuyvesant High School, 10/06/01.
8 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270808
TEM asbestos analysis for New Stuyvesant High School exterior/interior, received 10/24/01.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000292752
TEM analysis with air volume and opening details for exterior/interior of New Stuyvesant H.S., 10/28/01.
8 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270431
TEM analysis of asbestos fibers from exterior and interior areas of New Stuyvesant High School, received 10/15/01.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270980
TEM asbestos analysis for exterior/interior of New Stuyvesant High School, received 10/28/01.
8 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000188482
Laboratory report detailing asbestos fiber analysis by TEM and EDS for exterior and interior building samples.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000270967
TEM asbestos analysis with SAED/EDS for New Stuyvesant HS exterior/interior, Oct 2001.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270853
TEM asbestos analysis for New Stuyvesant High School, Oct 2001.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270551
TEM asbestos analysis for exterior & interior of New Stuyvesant H.S.; includes sample numbers and date.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270810
TEM asbestos analysis, New Stuyvesant High School exterior/interior, received 10/24/01.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293940
TEM analysis of air samples at New Stuyvesant HS, exterior/interior, Oct 2001.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270258
TEM analysis of exterior facade at New Stuyvesant High School, 10/06/01.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
TEM asbestos analysis report for exterior/interior of building, Oct 2001.
Similar indexed content
TEM asbestos analysis with SAED/EDS for New Stuyvesant HS exterior/interior, Oct 2001.
Similar indexed content
NYC-WTC_000270853
TEM asbestos analysis for New Stuyvesant High School, Oct 2001.
Similar indexed content
TEM asbestos analysis for exterior & interior of New Stuyvesant H.S.; includes sample numbers and date.
Similar indexed content
TEM asbestos analysis, New Stuyvesant High School exterior/interior, received 10/24/01.
Similar indexed content