TEM analysis lab report, 1 page, Oct 2001

Machine-extracted title · confidence 28%

TEM analysis details for lab sample 62074, instrument and area data.

NYC-WTC_000270787
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ATC ASSOCIATES INC. TEM ANALYSIS LAB GROUP #: 5748 - 10/23/01

Lab Sample No. 62^ Filter Type MCE 25 mm Operator Client Spl. No. 18 Filter Area 3S5 rnrr.^2 -(■■/if Instrument I.D. 5M 10 CRX Grid I.D. Disk No. Screen Magnification 16,4Q0X (GO) Area 0.Q1I24 mm"2 Comments

Acc. Voltage 80 kV No. GO to be Analyzed 4 ( 3.147 5crucc■ Corspd. to 70 5/mm^2.)

Length I.D. of Structure EDS n or GO. Structure Structure Type (Nonasb. No Coord. No. ^0.5 um F B C M < 5 um Sum Chrys. Amphibole Nonasb. Ambig./ND Elements)

21

3

—Photo No. (from 1 in S asbestos- Identify all structures using EDS Check diffraction for aabeatoa Store all unrepeated spectra— containing samples) Grid acceptance:! structures up to 70q/t?im (lit ■•) <50% undiSBolved filter, overlapped or folded Struct. = > 0.3um & > 3:1 Aspect Ratio <10% particulate coverage >SO% coverage Totals N= Not Observed (EDS spectrum or dlffrsctlon pattern) at least 20 unfolded or overlapped grid squares Positive diffraction pattern properties conforming <3% holes or opaoue areas F B C M > Sum to laboratory identification criteria observed. Inuaed portion Por ehrysoUle! 0.73nm spacing for (OZO) raflecUona. or rnur Chrysotile a.a3nm tpaeing for the layer line repeoL, Btreaking -Avoided portion Of (HO) and (130) renections. of niter For amphiboles: 0.33nm layer line repeat, and approx. Portion of filter (2mm wide) 3.S ratio of non-twinned layer line spot spacing to subject to ' Amphibole layer Una repeat distance (O.SSnm). examination

EDS spectrum conforming to laboratory Ambiguous identification criteria observed. AMPHIBOLES P= Single Fiber (1-3 intersections s 1-3 fibers) Amosite B= Bundle f>3 fibers <1 fiber diameter apart) ____________ 23mm flllar Crocidolite Non-asbestos S- SSST ,------- l5Loppln,“Hule.r“l------- Anthophyllite NSD= No Structure. Detected | >50 »/C-Q- or in IsL 4 C.O. | Tremolite Actinolite Non-ldentified U\DATA\PRlVA-re\MIKBC\CAD0\TEM3 9/22/00

CITY_21MC100_011107789

NYC-WTC_000270787

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000270787Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000294042

TEM analysis parameters and structural context for sample 62405.

Similar indexed content

NYC-WTC_000270685

TEM analysis with EDS; asbestos fiber assessment for New Stuyvesant H.S., Oct 2001.

Similar indexed content

Compare copies and versions →