10/31/2001 12:41 6314676905 PEDNEAULT ASSOCIATES PAGE 10

r Prepared Exclusively Por PEDNEAULTASSOCIATES, INC NYCDEP-Emergeiicy Response & Tech Assmt. ISISWNTHAVEWE. BOX205. NX //7/^ 96 05 Horace Harding Expressway LAB#: 01100535 Corona NY 11368 PROJECT ID WORLD TRADE CENTER- 5 Boro Sampling (718) 595-465(1 MATRIX: AIR\GAS

I m,p-Xylene 1.14 ppb v/v 0.1705 USEPA TO-15 10/30/01 Styrene 0.14 ppb v/v 0.0896 USEPA TO-15 10/30/01 1,1,2,2-Tetrachloroethane ND ppb v/v 0.1471 USEPA TO-15 1030/01 0-Xylene 0.37 ppb v/v 0.0111 USEPA TO-15 10/30/01 1.3,5-Trimethylbenzerie 0.10 ppb v/v 0.0757 USEPA TO-15 10/30/01 1,2.4-Tr(methylbenzerie 0.29 ppb v/v 0.1511 USEPA TO-15 1030/01 1,3-Dichlorobenzen0 ND ppb v/v 0.1564 USEPA TO-15 10/30/01 1,4-Dichtoroben2ene ND ppb v/v 0.169 USEPA TO-15 10/30/01 1,2-Dlchlorobenz0ne ND ppb v/v 0.2014 USEPA TO-15 10/30/01 1,2.4-T richlorobenzen e ND ppb v/v 0.1785 USEPA TO-15 1030/01 Hexachloro-1,3-Butadiene ND ppb v/v 0.1976 USEPA TO-15 10/30/01 Tentatively Identified Compounds USEPA TO-15 10/30/01 {E)-2-ButenaI 1.25 ppb v/v USEPA TO-15 1030/01

John Pedneault f’age 6 of 16 ND=RESULT IS EQUAL TO OR LESS THAN MDL Lab Director NYS ELAP #10224 NR=NON REPORTABLE RESULTS VWBE #46075

CITY_21MC100_011107536

NYC-WTC_000269772

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000269772Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →