NYC 9/11 Public Portal Document
AMBIENT GROUP
Dioxins/Forans, HRGC/HRMS (8290)
Client Sample IDs 211909-12D
Lot-Sample #..4 G2D190191-012 Work Order EX6VP1AA Matrix,...: SOLID
Date Sampled...: 04/18/02 Date Received..: 04/19/02 Instrument: 5D5
Prep Date.—: 04/19/02 Analysis Date..: 04/24/02 Unlts..w.: pg/g
Prep Batch 2109509 Dilation Factor: 1 % Moisture:
DETECTION TEF TEQ
UMn FACTOR CONCENTRATION
PARAMETER RESULT
2,3,7,8-TCDD 1100 1.000 1,100.000000
1,23,7,8-PeCDD 4000 0.500 2,000.000000
1,23,4,7,8-HxCDD 3100 0.100 310.000000
1,23,6,7,8-HxCDD 5000 0.100 500.000000
1,23,733-HxCDD 4800 0.100 480.000000
133,4,6,7,8-HpCDD 27000 0.010 270.000000
QCDD 52000 0.Q0i 52.000000
23,7,8-TCDF 5600 CON 0.100 560.000000
133,7,8-PeCDF 6900 0.050 340.000000
23,4,7,8-PeCDF 8900 0.500 4,400.000000
1,23,4,7,8-HxCDF 11000 0.100 1,100.000000
1,23,6,7,8-HxCDF 9600 0.100 960.000000
23,4,6,7,8-HxCDF 8800 0.100 880.000000
1,2,3,7,8,9-HxCDF 840 0.100 84.000000
1,23,4,6,7,8-HpCDF 38000 0.010 380.000000
1,23,4,7,8,9-HpCDF 4400 0.010 44.000000
OCDF 20000 0.001 20.000000
Total TEQ Concentration 13,480.000000
PERCENT RECOVERY
INTERNAL STANDARDS RECOVERY LIMITS
13C-23,7,8-TCDD 57 40-135
13C-l,2,3,7,8-PeCDD 55 40-135
l3C-l,23,6,7.8-HxCDD 50 40-135
13C.1.23.4,6,7.8-HpCDD 63 40 -135
13C-OCDD 69 40-135
13C-23,7,8-TCDF 43 40-135
13C-l,2,3.7,8-PeCDF 61 40-135
13C-l,23,4,7,8-HxCDF 52 40-135
13C-l,2,3,4,6,7,8-HpCDF 63 40 -135
Notes:
TEF values are cited in U.S, Environmental Proteclion Agency, (1989) Ihterfia^i^cediBsa iwcsiiroaJiag risks associated with exposures to mixtures ofchlorinated
EPA^^9^™** (CDDs and CDFs) and 1989 update. U.S. Envi»on»entai Protection Agency, Risk Assessment forum, Washington, DC:
CON Confirmation analysis.
Sac_SttKl_TE<3JtPT Rev.o IVI0/2001
CITY_21MC100_003251765
NYC-WTC_000269294
OCR can misread numbers and units. Confirm readings against the page image before using them.