NYC 9/11 Public Portal Document
AMBIENT GROUP
Diosins/Furaas, HRGCZHRMS (8290)
Ctient Sample ID: 211909-10D
Lot-Sample G2D19O191-010 Work Order#-.! EX6VM1AA Matrix—; SOLID
Date Sampled...: 04/18/02 Date Received-: 04/19/02 Instrument: 5D5
Prep Date......: 04/19/02 Analysis Date..; 04/24/02 Units—.: Pg/g
Prep Batch 2109509 Dilation Factor: 1 % Moisture;
DETECTION TEF TEQ
LIMIT FACTOR CONCENTRATION
PARAMETER RESULT
2,3,7,8-TCDD 840 1.000 840.000000
1,2,3,7,8-PcCDD 2200 0.500 1,100.008000
1,2,3,4,7,8-HxCDD 2000 0.100 200.000000
1,2,3,6,7,8-HxCDD 4200 0.100 420.000000
1,23,7,8,9-HxCDD 2600 0.100 260.000000
1,23,4,6,7,8-HpCDD 30000 0.010 300.000000
OCDD 72000 0.001 72.000000
23,7,8-TCDF 4600 CON 0.100 460.000000
1,2,3,7,8-PeCDF S300 0.050 260.000000
2,3,4,7,8-PeCDF 6400 0.500 3;zoo.oooooo
1,23,4,7,8-HxCDF 13000 0.100 1300.000000
1,23,6,7,8-HxCDF 8200 0.100 820.000000
2,3,4,6,7,8-HxCDF 10000 0.100 1,000.000000
1,23,7,8,9-HxCDF 510 0.100 51.000000
1,23,4,6,7,8-HpCDF 55000 0.010 550.000000
1,23,4,7,8,9-HpCDF 5200 0.010 52.000000
OCDF 45000 0.001 45.000000
Total TEQ Concentration 10,930,000000
PERCENT RECOVERY
INTERNAL STANDARDS RECOVERY UMITS
13C-2.3,7.8-TCDD 54 40-135
13C-l,2,3,7,8-PeCDD 53 40 -135
13C-l,2,3,6,7,8-HxCDD 58 40 -135
13C-1.2,3,4,6,7.8-HpCDD 60 40-135
13C-OCDD 61 40-135
13C-2,3.7,8-TCDF 42 40 -135
13C-l,2,3,7,8-PeCDF 54 40 -135
13C-l,2,3,4,7,8-HxCDF 48 40-135
13C-l,2,3,4.6,7,8-HpCDF 58 40-135
Notes;
TEP values m cited in U.S. Environmental Protection Agency, (1989) Interim procedures for estimating risks associated with exposures to mixtures of chlorinated
dibetizo-p-dtoxins and -dibenzoiitrant (CDDs and CDFs) and 1989 update. U.S. Environmental Protection Agency, Risk Assessment forum. Washington, DC!
EPA/625/3-89/016.
CON Confirmation analysis.
S«_Slnd_TEQ.iirr R«v,0 11/10/2001