Respirable Silica: The overwhelming majority of 849 silica samples (excluding bulk and blank
samples) show no detectable levels of airborne silica. However, 54 exposures
exceeded the PEL. The highest sample result was approximately twenty-one
times the OSHA limit (jack hammering concrete 16 feet below grade). The
other elevated exposures were approximately one to fourteen times the
OSHA limit. These exposures occuned during: 1) pre-drilling /slurry wall 2)
jack hammering, 3) rubble removal and loading operations near the Winter
Garden; 4) during the breaking up of concrete in the pit; 5) while drilling the
concrete slurry wall, 6) flagging operations in pit, and 7) while chipping
concrete with power tools during demolition activities at 7 WTC’s parking
garage. Most of the work areas where apparent overexposures to silica
occurred were in the rubble pile/pit; an area where OSHA continues to
encourage the use of respiratory protection.
Organic
Compounds: OSHA has taken a total of 652 samples (excluding bulk and blank samples)
for organic compounds such as acetaldehyde, acrolein, acrylonitrile, benzene,
2-butanone, carbofurans, dioxin, PCBs, ethyl benzene, formaldehyde. Freon
R-22 (chlorodiflouromethane), hexone, isocyanates (e.g. MDI, TDI),
perchloroethylene, polynuclear aromatics, phosgene, styrene, toluene, 1-3
butadiene, trichloroethylene, vinyl chloride, glutaraldehyde, and xylene.
Screening samples initially showed elevated levels of some organic chemicals
resulting from the fires burning in the rubble pile. Subsequent personal and
area samples show worker exposure levels to be below OSHA limits.
However, one personal sample result for a benzene sample taken was found to
be at the 8-hr. OSHA Allowable Limit concentration of 1 ppm. This was
found on a backhoe operator moving debris on 10/7/01. See information
below for the specific counts in regards to polynuclear aromatics. Freon R-22,
phosgene and dioxin.
Dioxins: OSHA has taken 10 dioxin samples (excluding blanks) in the plume over hot
spots in (and around the perimeter of) the rubble pile. Dioxin levels detected