NYC 9/11 Public Portal Document
RB-SERIES
VENT-SCRUB™
AB-^tfiESSURE DROP (CC601 4 X 8)
SPECIFICATIONS: RB-IO RB-20 14
Outside Dimensions (LxWxH): 19’-9”x8’-0”x7’-9” 23’-7” X 8’-6” X 9’-8” 12
Inlet/Outlcd” (I.D.) 12”x36” I8”x48” _10
Manway Retractable or Fixed Roof^’i (two) 24” X 48’’ 1.-
Interior Coating Cross Linked Acrylic ' Fusion bonded epoxy
I •■
Exterior Coating Enamel Enamel UI
5 ♦ -
Cross Sectional Area (Sq. Ft.) 133 161 (0
W 2 -
Empty Weight (lbs.) 9500 9500 (C
o.
Approx. Carbon Capacity (lbs.) 3’ Bed Depth 12,000 15,000 0 5 Toy2000 3«» 4000 5000 W 00 7000 SOOIk 9000 10000
FLOWRATE (SCFM)
Approx. Carbon Capacity (lbs.) 4’ Bed depth 20,000
RB-20 PRESSURE DROP (CC6D1 4x8)
14
OPERATING SPECIFICATIONS:
Flow, SCFM (max.) 8000 10,000 r
g’O
Pressure, inches w.c. (max.) 28 28 z
? 8
Vacuum, inches w.c. (max.) 2 2 O
□ e
Temperature, F (max.) 140 140
'I’Can be adapted with 8”, 10” or 12” 150# flanged connections for thcRB-l id with 8", 10", I I-
or 14” 150# flanged connections for the RB-20.
'^Yixed roofs are available with two 24” manways.
I- 0 . _ .
0 1200 2400 3600 4800 6000 7200 8400 9600 1060012000
FLOWRATE (SCFM)
Monitoring and Service When an adsorber exchange is required,
U.S. Filter/Westates can provide moni a fresh adsorber will be delivered from 3
toring services utilizing the appropriate
type of field monitoring equipment.
any one of our four convenient region
al locations. The adsorber containing
1)
J
The monitoring method used and spent carbon is removed from the site
equipment required will depend on using a roll-off trailer and shipped to
the types of VOC’s being captured our reactivation facility where the
and on the regulatory compliance adsorber is emptied, inspected, refilled
requirements. and the spent carbon is reactivated and
recycled. -
The frequency of adsorber exchange
will depend on operating parameters Please contact your nearest
that affect carbon loading such as U.S. Filter/Westates account represen
VOC type and concentration, temper tative for a process and economic
ature, relative humidity, superficial gas evaluation of the suitability of using
velocity, carbon type (coconut shell or
bituminous coal) and other factors,
the RB-Scrics adsorbers in your
particular application.
U.S.FI1 =;s
WESTATES
U.S. Filter/Westates offers state-of-the-
All information presented herein is believed reliable and
art computer modeling programs, for
in accordance with accepted engineering practice.
U.S. Rltcr/Wcstatcs makes no warranties as to com U.S.Filter/Westates
carbon usage estimates and optimiza
pleteness of information. Users arc responsible for evalu
ating individual product suitability for specific applica Baytown, TX 800-659-1723
tion of system performance.
tions. US. FilierfWcstato assumes no liability whatsoev Warren, NJ 800-659-1717
er for any special, indirect or consequential damages
arising from the .sale, resale or misuse of its products. LosAngeles, CA 800-659-1771
Oakland, CA 800-659-1718
CITY_2IMCl0 0_0 00016780
NYC-WTC_000268807
OCR can misread numbers and units. Confirm readings against the page image before using them.