Bulk sample analysis, 346 Broadway, Sept 2001

Machine-extracted title · confidence 41%

Bulk sample analysis results for 346 Broadway project, lab IDs 010917E-857 to -861.

NYC-WTC_000268315–000268318
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

KAMCONSUHANTS 35-40 36th Street Long Island City NewYork, 11106 Tel: (718)729-1907 Fax:(718)729-1875 ■‘ML

BULK SAMPLE ANALYSIS REPORT CLIENT: NYC-DCAS BUILDING ADDRESS: OFFICE BLDG. - 346 Broadway PRO.IECT#: Client Sample ID# : 11 12 13 14 15 Lab Sample ID# ; 0!0917E-8o7 0I09I7E-868 010917E-S69 0I0917E-870 010917E-87I Samp le Location: 3rd Floor 3rd Floor 3rd Floor Street Level Street Level South Windows Stair "A" Stair "B" Broadway Lobby Mid Lobby By Between Elevators Entrance Elevators

Homogeneity: Yes Yes Yes Yes Yes

Sample Description: Sill Floor Floor Floor Floor U'ipe Wipe Wipe Wipe Wipe

Color: BIk Blk BIk Blk Blk Texture: Mixed Mixed Mixed Mixed Mixed Sample Treatment: None None Nene None None

Asbestos Present: (Type & Percent) ND ND ND ND ND Total Percent Asbestos: 0% 0% 0% 0% 0%

Other Fibr. Mat. (Type & Percent): 5%SYNTH 5%SYNTH 3%SYNTH 5%SYNTH 3%SYNTH 4%CELL Non Fibr. Mat. (Percent): 91% 95% 97% 95% 97% Date Received: 9/17/01 Date of Analysis: 9'17/0! Date of Report: 9'17/01

Analyst: Lab Manager RoodyYouis DaviiTChen * Analysis of samples is performed byrolarized Light Microscopy (PLM) - Point Counting Method (EPA 600/M4-82-020) X * Analytical equipments; Stereobinocular microscope (MEIJI EMT-Serial # 25930), Polarized Light Microscope (MEIJI ML-POL-Serial # 88034) * PLM is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials. Quantitative transmission electron microscopv is currently the only method that can be used to determine if this material can be considered or treated as non-asbestos-containing ♦ Samples will be stored for ninety (90) days and then returned to the client upon request * The results relate only to the items calibrated or tested. * The certificate of report shall not be reproduced without the written approval of the laboratory. * The report must not be used by the client to claim endorsement by NVLAP or any agency of the US Government. W NYS-DOH ELAP #11273 NIST-NVIAP # 10204'7 AIHA#: 100269

3

CITY_21MC100_006262598

NYC-WTC_000268317

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000268317Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →