NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 11 pages

Bulk sample analysis, 280 Broadway, Sept 2001

Machine-extracted title · confidence 40%

Bulk sample analysis results for 280 Broadway project, lab IDs 010922B-1389 to -1393.

NYC-WTC_000268289–000268299
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

KAM CONSULTANTS 35-4036th Street Long Island City NewYork.mOfi Tel: (718)729-1997 Fax: (718)729-1876

BULK SAMPLE ANALYSIS REPORT CLIENT: NYC-DCAS BUILDING ADDRESS: 280 Broadway, Manhattan, NY PROJECT#: Client Sample ID# ; 46 47 48 49 50 Lab Sample ID# ; 010922B-1434 010922B-1435 0109226-1436 010922B-1437 010922B-1438 Sample Location: Stairs B Lobby 1st Floor 1st Floor 1 st Floor 1st Floor North Window South Window Chambers Street Tool Box Entrance Door NortIr'East Hall Homogeneity: Yes Yes Yes Yes Yes Sample Description: Floor Window Sill Window Sill Door Step Box Surface Wipe Wipe Wipe Wipe Wipe

Color: BIk BIk Blk BIk BlkZBrn Texture: Mixed Mixed Mixed Mixed Mixed Sample Treatment: None None None None None

Asbestos Present: (Type & Percent) ND ND ND ND ND Total Percent Asbestos: 0% 0% 0% 0% 0% Other Eibr. Mat. (Tj’pe <& Percent): 1%CELL lO’/oCELL 2%CELL 2%CELL 1%CELL 1%SYNTH Non Fibr. Mat. (Percent): 99% 90% 98% 98% 98% Date Received: 9/22/01 - Date of Analysis: 9/23/01/) Date of Report: 9/24/01/ i

Analyst: ____ Mark Ulanecki David Chen * Analysis of samples is nerfortned by Polarized Light Microscopv ( PLM) - Point Counting Method (EPA 600/M4-82-020) / * Analytical equipments: Ster/obinocular microscope (MEIJI EMT-Serial # 25930), Polarized Light Microscope (MEIJI ML-POL-Serial # ^8034) * PLM is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials. Quantitative transmission electron microscopy is currently the only method that can be used to determine if this material can be considered or treated as non-asbestos-containing * Samples will be stored for ninety (90) days and then returned to rhe client upon request * The results relate only to the items calibrated or tested. * The certificate of report shall not be reproduced without the written approval of the laboratory. * The report must not be used by the client to claim endorsement bv NVLAP or any agency of the US Government. NYS DOH ELAP 11273 MST-NYLAP# 102047 AIHA H: 100269

10

CITY_21MC100_0 06262560

NYC-WTC_000268298

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000268298Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →