Bulk sample analysis, 253 Broadway, Oct 2001

Machine-extracted title · confidence 42%

Bulk sample analysis results for 253 Broadway project, listing lab IDs 010917C-890 to -894.

NYC-WTC_000268280–000268284
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

KAMCONSULIANTS 35-40 36th Street Long Island City NewYork, 11106 Tel: (718)729-1997 Fax:(718)729-1876

BULK SAMPLE ANALYSIS REPORT CLIENT: NYC-DCAS BUILDING ADDRESS: OFFICE BLDG. - 253 Broadway, Manhattan, NY PROJECT#: Client Sample ID# : 11 12 13 14 15 Lab Sample ID# : 010917C-900 010917C-901 010917C-902 0109;7C-903 010917C-904 Sample Location; 9th Floor Stairs "C" 9th Floor 7th Floor Stairs "B" Stairs "B" 9th Floor By Elevators Stairs "A" 7th Floor

ilomogeneit;.-: Ye; Yes Yes Yes Yes Sample Description: Floor Floor Floor Floor Floor Wipe Wipe V/ipe Wipe Wipe

Color: BIk BIk Blk BIk BIk Texture: Mixed Mixed Mixed Mixed Mixed Sample Treatment: None None None None None

W Asbestos Present: (Tyfie & Percent) ND ND ND ND ND Total Percent Asbestos: 0% 0% 0% 0% 0%

Other Fibr. Mat. (Typie & Percent): 10%SYNTH 10%SYNTH 5%SYNTH 15%SYNTH 15%SYNTH 5%CELL 10%CELL 2%CELL 5%CELL 10%CELL Non Fibr. Mat. (Percent); 85% 80% 93% 80% 75% Date Received: 9/17/01 Date of Analysis: 9/17/01 Date of Report: 9/17/01

Analyst: Lab Manager: 1^,..__ / A Roody Loi David Chen * Analysis of samples is performed by irized Light Microsconv (PLMI - Point Counting Method (EPA 600/M4-82-020) * Analytical equipments: Stereobiilocular microscope (MEIJI EMT-Serial # 25930), Polarized Light Microscope (^4EIJI ML-POL-Serial # 88034) * PILM is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials. Quantitative transmission electron microscopy is currently the only method that can be used to determine if this material can be considered or treated as non-asbestos-containing * Siimples will be stored for ninety (90) days and then returned to the client upon request * The results relate only to the items calibrated or tested. * The certificate of report shall not be reproduced without the wTitten approval of the laboratory. * The report must not be used by the client to claim endorsement by NVLAP or any agency of the US Government. NYS-DOH ELAP # 11273 NIST-NVLAP if 102047 AlHAff: 100269

3

CITY_21MC100_006262540

NYC-WTC_000268282

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000268282Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →