NYC-WTC_000246268
TEM asbestos analysis report for air sample from TRC job 202011870.
4 shared non-person entities · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗Asbestos monitoring project chain-of-custody form, lab details.
NYC-WTC_000267788–000267859OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
TEM Asbestos (air) Count Sheet sample area analyzed e [ Client Name: TRC Environmental Corporation Job #: 202011870 Volume (liters): 1 247.7 Lab Sample #: 56 Filter Type / Filter Area: MCE 385 mm2 Client Sample #: SN01102ASBAIR0310 Grid Opening Size: 0.01000 Received: 01/12/2002 09:41:24 Area Examined: 0.07000 mm2 Date Analyzed: 01/14/2002 Magnification: 20,000 Scope #: Ac:celerating Voltage: 100 KeV Analysis Performed by: Aleksandr Barengolts Location Grid Fiber Length Width Opening gM juM Fiber Type tJorpiiology EDS Orient. SAED Photo C9-4/4B 1 NSD C9-4/4C 2 NSD U C9-4/4E 3 NSD u C9-4/4F 4 NSD u C9-4/4G 5 NSD u C9-4/4H 6 NSD u C10-5/4E 7 NSD u
NSD: No Asbestos Structures Detected Comments Structure Density Concentration Total Grid Openings: 7 (str/mm2) (str/:c air) Grid Evaluation Ohrysotile Asbestos Structures: 0 <14.3 <0.0044 Grid Openings Covered > 50% ®l?mphibole Asbestos Structures: 0 <14.3 <0.0044 1^ Intact Grid Opening > 50% Asbestos Structures >=5 microns: 0 <14.3 <0.0044 Undissolved Filter < 10% Total Non-Asbestos Structures: K Folded Replica < 50% Total Asbestos Structures: 0 <14.3 <0.0044 El Filter Loading < 10% Analytical Sensitivity: 14.3 0.0044 E Particulate Even CITY_21MC100_0 06261744
NYC-WTC_000267849
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
No available related records indexed in this group.
NYC-WTC_000246268
TEM asbestos analysis report for air sample from TRC job 202011870.
4 shared non-person entities · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000246317
TEM asbestos analysis report for air sample TRC Lab Sample 56.
4 shared non-person entities · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000246302
TEM asbestos analysis report for air sample from TRC job 202011870, Lab Sample 41.
4 shared non-person entities · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000235339
Table I: Summary of TEM results for asbestos in air at 100 Church Street, NYC Law Department.
7 shared non-person entities · 1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000235611
Laboratory report summarizing TEM analysis results for asbestos air samples from 100 Church Street.
7 shared non-person entities · 1 shared topics · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000235235
Laboratory report summarizing transmission electron microscopy results for asbestos analysis of air samples from 100 Church Street.
5 shared non-person entities · 1 shared topics · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000174343
Summary table of transmission electron microscopy results for asbestos fibers in air samples collected at 100 Church Street.
6 shared non-person entities · 1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000235411
Laboratory report summarizing transmission electron microscopy results for asbestos in air samples collected by TRC Environmental Corporation.
6 shared non-person entities · 1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000235675
Summary table of transmission electron microscopy (TEM) results for asbestos air samples collected at 100 Church Street in February 2002.
6 shared non-person entities · 1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000235552
Summary of transmission electron microscopy results for asbestos analysis in ambient air samples collected at the specified location.
6 shared non-person entities · 1 shared topics · similarity 0.988
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000235238
Laboratory report summarizing transmission electron microscopy results for asbestos analysis of ambient air samples from 100 Church Street.
5 shared non-person entities · 1 shared topics · similarity 0.988
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000235246
Laboratory report summarizing transmission electron microscopy results for asbestos analysis of air samples from 100 Church Street.
6 shared non-person entities · 1 shared topics · similarity 0.988
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000235243
Laboratory report documenting PCM microscopy fiber counts for ambient asbestos air samples collected at 100 Church Street.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000235545
Laboratory report detailing transmission electron microscopy analysis of ambient air samples for asbestos fibers at 100 Church Street.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000235675
Summary table of transmission electron microscopy (TEM) results for asbestos air samples collected at 100 Church Street in February 2002.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000235339
Table I: Summary of TEM results for asbestos in air at 100 Church Street, NYC Law Department.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000235679
Summary table of transmission electron microscopy (TEM) results for asbestos air samples collected at 100 Church Street in March 2002.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000235414
Laboratory report summarizing transmission electron microscopy results for asbestos in air samples collected by TRC Environmental Corporation.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000246268
TEM asbestos analysis report for air sample from TRC job 202011870.
Similar indexed content
NYC-WTC_000246317
TEM asbestos analysis report for air sample TRC Lab Sample 56.
Similar indexed content
NYC-WTC_000246302
TEM asbestos analysis report for air sample from TRC job 202011870, Lab Sample 41.
Similar indexed content
NYC-WTC_000235339
Table I: Summary of TEM results for asbestos in air at 100 Church Street, NYC Law Department.
Similar indexed content
NYC-WTC_000235611
Laboratory report summarizing TEM analysis results for asbestos air samples from 100 Church Street.
Similar indexed content