NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 72 pages

Asbestos monitoring, chain of custody form

Machine-extracted title · confidence 37%

Asbestos monitoring project chain-of-custody form, lab details.

NYC-WTC_000267788–000267859
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

Aciuau : 2U2011870 Z z Client nB TRC Environmental Corporation O ■< ( CD o Tablk g Summary of Transmission Electron Microscopy (TEM) Results for Asbestos (air) ■D 1^ c o 35052-0000-(X)002; New York City Law Department; 100 Church Street, New York, NY CT

o o' o Structure Stiucture ■a ro Air Area * Analytical Asbestos Structures Detected Density o o> Concentration Type 3. 03 SciLab Client Dilution Filtered Analyzed Sensitivity (Microns) (struc/sq mm.) (struc/cc air) of CD 00 Sample # Sample # Factor (liters) (sq. mm.) (struc/cc air) 05-5.0 >5.0 Total >5.0 Total >5.0 Total Asbestos O o o 43 SNOilO2ASBAIRO4O7 0 0038 0.0 0.0 c 1435 .07 0-0 <14.3 <14.3 <0.0038 <0.0038 NSD 3 NW Comer CD

44 SNOi IO2ASBAIRO4O8 1310 .07 0.0042 0.0 0.0 0.0 <14.3 <14.3 <0.0042 <0.0042 NSD West Wall Middle 45 SN01102ASBAIR0409 1540 .06 0.0042 0.0 0.0 0.0 <16.7 <16.7 <00042 <0.0042 NSD Center Hallway East 46 SNO1IO2ASBA1RO41O 1232 .07 0.0045 0.0 0.0 0.0 <14.3 <14.3 <0.0045 <0.0045 NSD Center Hallway West 47 SNO11O2ASBAIRO3O1 1523 .06 0.0042 0.0 0.0 0.0 <16.7 <16 7 <0.0042 <0.0042 NSD SW Comer 48 SNOI 1O2ASBAIRO3O2 1060 .08 0.0045 0.0 0.0 0.0 <12.5 <12.5 <0.0045 <0.0045 NSD South Wall Middle 49 SNOI 1O2ASBAIRO3O3 1505 .06 0.0043 0.0 0.0 0.0 <16.7 <16.7 <0.0043 <0.0043 NSD SE Comer 50 SNOI 1O2ASBAIRO3O4 1326 .07 0.0041 0.0 0.0 0.0 <14.3 <14.3 <0.0041 <0.0041 NSD Fast Wal! Middle 51 SNOI 1O2ASBA1RO3O5 1626 .07 0.0034 0.0 0.0 0.0 <14.3 <14.3 <0.0034 <0.0034 NSD NE Corner 52 SNO11O2ASBAIRO3O6 1617 .08 0.0030 0.0 0.0 0.0 <12.5 <12.5 <0.0030 <0.0030 NSD North Wall Middle S3 SN011O2ASBAIR0307 1195 .07 0.0046 0.0 0.0 0.0 <14.3 <14.3 <0.0046 <0.0046 NSD NW Comer 54 SNOI IO2ASBAIR0308 1342 .06 0.0048 0.0 0.0 0.0 <16.7 <16.7 <0.0048 <0.0048 NSD West Wall Middle o 55 SN01102ASBAIR0309 1326 .06 0.0048 00 0.0 0.0 <16.7 <16.7 <0.0048 <0.0048 NSD H Center Hallway East 1 hJ 56 SN0IIO2ASBA1R03IO 1247 .07 0.0044 0.0 0.0 0.0 <14.3 <14.3 <0.0044 <0.0044 NSD Center Hallway West o + concentration represented by the detection of 1 structure o I ** not analyzed o o NSD: No Asteslos Structures Detected Reviewed By: ; Analyzed By:. CD Aleksandr Barengolts NVLAP#: 200546-0 cn CD co

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000267798Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →